Instruction and Operation Manual
19
MAINTENANCE
Disassembly of LMV-313
STEP 1
Remove the nuts from the pump casing
studs. Lift the gearbox and seal housing up
off of the pump casing. Remove o-rings 936B
and 936CB and backing ring 70B.
When lifting, if the pump case and seal housing
are difficult to separate, use the three jacking
screws to break the seal.
STEP 2
Install the anti-rotation device to prevent
impeller from spinning.
Note: Locking tools, part number TO01AK03
for splined or TO01AK02 for coupled
shafts, are available for purchase from
Sundyne Corporation.
STEP 3
Remove the inducer.
Note
: All inducers have a left-handed thread
.
Note: When working on a pump with a
tapered inducer, the inducer must be
removed before the diffuser can be
removed from the seal housing.
Содержание LMV-313
Страница 1: ...SUNDYNE LMV 313 PUMPS Instruction and Operation Manual August 2007 ...
Страница 36: ...Instruction and Operation Manual 32 Figure 15 Inducer Housing Shim Adjustment ...
Страница 40: ...Instruction and Operation Manual 36 Figure 17 Service Check Points ...
Страница 69: ...Instruction and Operation Manual 65 Figure 22 Gearbox Components ...
Страница 70: ...Instruction and Operation Manual 66 Figure 23 Pump Nomenclature ...
Страница 71: ...Instruction and Operation Manual 67 Figure 24 Exploded View ...
Страница 72: ...Instruction and Operation Manual 68 Shaft Assemblies Figure 25 Shaft Assemblies ...
Страница 74: ...Instruction and Operation Manual 70 Single Seal Arrangement and Parts Figure 27 Single Seal Arrangement ...
Страница 76: ...Instruction and Operation Manual 72 Double Seal Arrangement and Parts Figure 28 Double Seal Arrangement ...
Страница 78: ...Instruction and Operation Manual 74 Tandem Seal Arrangement and Parts Figure 29 Tandem Seal Arrangement ...