Pre-Start Up
Pressurizing the Fluid Loop
Pressurize the double seal buffer loop or
external seal flush, if applicable, prior to
admitting fluid into the pump casing.
Servicing the Gearbox
Fill the gearbox with lube oil up to a quarter inch
(¼) or 6 mm from the top of the oil level sight
glass.
Note: Prior to using lube oil, verify that it
conforms to acceptable lube oil
s
pec
ification standards. Refer to the
SPECIFICATIONS section in this
manual for more information.
Under normal operation, the lube oil level will
lower about a quarter inch more than when idle.
Additionally bubbles will appear at the top of the
sight glass.
Note: Sundyne recommends that gearbox
lube oil be changed at least every six
months.
For requirement information about priming the
lube oil system, refer to the start-up section in
this manual.
Auxiliary Lube Pump
If your pump includes an auxiliary lubrication
pump, unlock the electrical circuit and move it to
the “hand” position. Check for oil leaks and
recheck the oil level.
Setting the Valves
To set the pump to the designated operating
point, start the pump with the suction valve in
the open position while throttling the discharge
valve.
Operating Conditions
Verifying Operating Conditions
Verify the following parameters against the
specifications on the specification sheet:
•
Suction
pressure
•
Suction
temperature
•
Discharge
pressure
•
Total
head
•
Flow
rate
•
Power
consumption
•
Specific
gravity
•
Viscosity
•
Net Positive Suction Head (NPSH)
The status of these conditions will significantly
alter performance of the pump if they are not in
accordance with the specification sheet.
Check with your Sundyne representative if the
operation conditions of your pump must run
under different parameters than indicated by the
specifications on the specification sheet.
Adjusting the Cooling Flow
If your model pump includes an installed heat
exchanger for the gearbox, adjust the cooling
flow to keep the temperature of the gearbox
sump at 140°-160°F (60°-71°C). Maximum
recommended temperature is 180ºF (82ºC).
Содержание LMV-313
Страница 1: ...SUNDYNE LMV 313 PUMPS Instruction and Operation Manual August 2007 ...
Страница 36: ...Instruction and Operation Manual 32 Figure 15 Inducer Housing Shim Adjustment ...
Страница 40: ...Instruction and Operation Manual 36 Figure 17 Service Check Points ...
Страница 69: ...Instruction and Operation Manual 65 Figure 22 Gearbox Components ...
Страница 70: ...Instruction and Operation Manual 66 Figure 23 Pump Nomenclature ...
Страница 71: ...Instruction and Operation Manual 67 Figure 24 Exploded View ...
Страница 72: ...Instruction and Operation Manual 68 Shaft Assemblies Figure 25 Shaft Assemblies ...
Страница 74: ...Instruction and Operation Manual 70 Single Seal Arrangement and Parts Figure 27 Single Seal Arrangement ...
Страница 76: ...Instruction and Operation Manual 72 Double Seal Arrangement and Parts Figure 28 Double Seal Arrangement ...
Страница 78: ...Instruction and Operation Manual 74 Tandem Seal Arrangement and Parts Figure 29 Tandem Seal Arrangement ...