13
P04
Parameter 4 is the session delay. The session delay allows a programmable amount of time at the
beginning of a session to get ready for the tanning session. The tanning session time shown on the timer
flashes during the session delay.
The unit comes with no session delay preprogrammed.
To Change Parameter 4, Session Delay
When parameter 04 is shown, the display will read 0.0 for no session delay
. To c
hange the session dela
y,
do the following:
Press
“Reset”
once then release it, the display will begin to flash. Now pres
s "up or "down"
to reach the
desired setting. Time is displayed from 0.0 to 10.0, with the decimal representing tenths
of a minute.
Example: 2.5 equals 2 minutes, 30 seconds
. After reaching the desired setting, press
“Reset”
once
and release it. Session delay is now set.
Now press
"up"
to reach
Parameter 5 (P05), the Station Address function.
P05
Parameter 5 is the st ation address. The station address allows the t anning unit to be identified for
interface with the CCS series controllers, the Intellitan Single Station Console, or the Intellitan Protocol
Interface (IPI) for your computer system.
The unit comes with a s
ta
tion address of zero (0)
preprogrammed, if you have multiple units each must be uniquely addressed.
To Change Parameter 5, S
t
ation Address
When parameter 05 is shown, the display will read 0000 for
stati
on address zero. To change the station
address, do the following:
Press
“Reset”
once and release it, the display will begin to flash. Now press
"up" or "down"
to reach
the
desired
address setting. Once the desired setting is reached press
“Reset”
once and release it. The
station
address is now set.
Now press
"up"
to reach
Parameter 6 (P06), the
Lamp-Hour Accumulation on
Current Lamp Bank
function.
P06
Parameter 6 is the lamp hour accumulation counter. The lamp hour accumulation counter keeps track of
the number of hours on the current lamp bank. This is a resettable parameter that should be reset to 0
when the lamps are changed. When current lamp hour accumulation reaches 0000, a beep will chime
each time the unit is turned on, indicating that a lamp change is necessary
. Chime will not sound if it has
been turned off through parameter 2. Parameter 6 is only edi
tab
le at password level 1.
When parameter 06 is shown, the display will read from 0000 to 9999.
To
clear the lamp hour accumulator,
do the following:
To Clear Parameter 6, Lamp Hour Accumulation
Press
“Reset”
once and release, the display will begin to flash. Now press and hold
s
until 0000 is
displayed. When the display reads 0000 pres
s
"Re
set”
once and release. Lamp hour accumulation is
now cleared.
Now press
"up"
once and release it to reach
Parameter 7 (P07), to measure A/C Voltage Phase A.
Parameter Detail
Содержание Radius 252
Страница 1: ......
Страница 2: ...1...
Страница 19: ...18 Wiring Diagram...
Страница 20: ...19 Relay Diagram...
Страница 21: ...20 Relay Panel A...
Страница 22: ...21 Relay Panel B...
Страница 23: ...22 Relay Panel C...
Страница 24: ...23 Relay Terminal Block...
Страница 25: ...24 Ballast Tray Connection...
Страница 26: ...25 Ballast Tray A1 B1 and C1...
Страница 27: ...26 Ballast Tray A2 and C2...
Страница 28: ...27 Ballast Tray B2...
Страница 29: ...28 Bed Cords...
Страница 30: ...29 Door Harness...
Страница 31: ...30 3 Phase Connection...
Страница 39: ......