11
To Change Parameters
To enter the System’s data bank, monitor operations and verify the vital functions concerning your unit,
use the following step-by-step instructions.
Note
: Each timer manufactured after 1995 displays the
current software version on power up.
These instructions are for level 2 and above of the Intellitan
Plus timer.
Enter Password Clearance
1.
Press (at the same time) then release
"up" and "down"
buttons; the display will change from 00:00 to 0000.
If
you cannot get the display to change to 0000, assure that you have disconnected the network cable(s)
from the timer. If power to the
tan
nning unit is not cycled on/o
ff
after disconnecting the network cable, you
must wait for thirty seconds for the timer to award access to the above mentioned buttons.
2.
Press the
“Reset”
button once so that 0000 begins to flash.
3.
Use the
"up"
button to enter the appropriate password to perform the desired function. Password 0010
(ten) must be entered to view parameters, and 0102 (one hundred and two) to edit parameters. After
entering the password press the
“Reset”
button. The display will stop flashing and 0001 (level one) or
0002 (level two) will appear in the display.
4.
Press the
“Start/Stop”
button to enter parameter mode, followed by the
"up"
button to reach the desired
parameter. If you go past a parameter you may press the
“Reset”
to return to the desired parameter.
Each time the
"up" or "down"
button is pressed the timer will displ
ay,
PX
X
(XX represents numbers)
representing
the parameter reached and the display will change showing the value of the
par
ameter.
5.
If you are using the second level password, press the
“Reset”
button to edit the parameter (once the
“Reset”
button is pressed the display will begin to flash). Use either the
"up" and "down"
button to set the
appropriate value for the
pa
rameter, then press
“Reset”
to exit the
pa
rameter.
6.
Press the appropriate
"up" and "down"
button to reach another parameter. You May press the
“Start/Stop”
button to exit the edit parameter mode.
Timer Edit Procedure
Содержание Radius 252
Страница 1: ......
Страница 2: ...1...
Страница 19: ...18 Wiring Diagram...
Страница 20: ...19 Relay Diagram...
Страница 21: ...20 Relay Panel A...
Страница 22: ...21 Relay Panel B...
Страница 23: ...22 Relay Panel C...
Страница 24: ...23 Relay Terminal Block...
Страница 25: ...24 Ballast Tray Connection...
Страница 26: ...25 Ballast Tray A1 B1 and C1...
Страница 27: ...26 Ballast Tray A2 and C2...
Страница 28: ...27 Ballast Tray B2...
Страница 29: ...28 Bed Cords...
Страница 30: ...29 Door Harness...
Страница 31: ...30 3 Phase Connection...
Страница 39: ......