2-12
SPARCserver 1000 System Board Manual—October 1994
2
4. Lift the SBus card from the socket at an angle while guiding the face plate
out from the back panel opening.
Refer to Figure 2-7.
5. Place the SBus card in an antistatic bag.
6. If the SBus card is not immediately replaced, install a filler panel (part
number 340-2305) on the back panel opening of the system board. To
secure the filler panel, use the screws that were removed in step 1.
Caution – Be sure to install the filler panel right-side up, installing it upside
down creates a gap at the top edge of the SBus slot opening that can impair
system cooling and regulatory compliance.
Figure 2-7
Removing or Installing an SBus Card
2.5.2 Installation or Replacement
Note – If the new SBus card has an adapter plate (refer to Figure 2-8), remove
the plate by performing the procedures in Section 2.5.2.1. If the SBus card does
not have an adapter plate, go instead to Section 2.5.2.2.
!
SBus card
Back panel screws