Sun Microsystems
Sun StorageTek ™ T9840D Tape Drive Security Policy
Physical Port
Qty
Logical interface
definition
Technical Specification
Host Interface
2
data input,
data output,
status output,
control input
This interface is used to transfer user data between the
ETD and the host. When the host transfers user data to
the ETD through this interface, the ETD encrypts and
writes the data to the magnetic media. When the host
receives user data from the ETD through this interface,
the ETD delivers data read from the magnetic media
that has been decrypted by the ETD. For details, see
[ETDIM].
The interface can be configured to support one of two
protocols:
1)
Fibre Channel, in accordance with the Fibre
Channel Protocol-3 (FCP-3), SCSI Primary Commands-
3 (see [SPC-3]), and SCSI Stream Commands (SSC-3)
specifications (see [SSC-3])
2)
FICON, in accordance with the Fibre Channel
Single-Byte Command Code Sets-3 Mapping Protocol
(FC-SB-3), Revision 1.6 specification (see [FC-SB-3])
Tape head
1
data input,
data output
Provides the interface to the magnetic tape media,
where the user data to be encrypted is written to, and
where the data to be decrypted is read from.
Tape media resides in six possible cartridge types:
1)
Standard Data
2)
SPORT (reduced length) Data
3)
VolSafe (write-once) Data
4)
Sport VolSafe Data (reduced length, write-once)
5)
Cleaning
6)
Diagnostic (used by a service representative).
Operator Panel
1
status output,
control input
The front of the ETD has an Operator Panel with the
following interface:
1. Four LED’s to provide status output:
1. Power Indicator
2. Activity Indicator
3. Clean Indicator
4. Service Indicator
2. An LCD display is used to display ETD status
and configuration menu text.
3. Four push button micro-switches.
1. IPL Switch
2. Unload Switch
3. Menu Switch
4. Select Switch
4. Manual Unload Device – screwdriver interface
for manually unloading a cartridge.
Power Interface
1
power input
100-240 VAC @ 50-60 Hz
Feb 5, 2010
Part 316055201, Rev: AA
Page 11