Chapter 8
Removing and Replacing Components
91
4. Tighten the captive screw on the back of the unit.
Memory Installation and Removal
There are four industry standard PC133 memory module sockets on the Sun Fire
V100 server’s system board. To see the location of the memory modules inside the
server, see
FIGURE 8-5
or the underside of the server’s top cover.
▼
To Install and Remove Memory
■
If the server is not in use, go straight to Step 1.
■
If the server is already in use, see “To Change Components In a Sun Fire V100
Server That Is In Use” on page 88.
1. Place the unit on an ESD surface and attach an antistatic wrist strap (see
FIGURE 8-2
)
2. Remove the server’s top cover (see “To Remove the Top Cover” on page 89).
3. Insert the memory module in the next vacant DIMM socket.
The memory slots are numbered 3, 2, 1, 0. Add DIMMS in that order.
FIGURE 8-5
DIMM Insertion and Removal Sequence
4. Press the memory module until the latches at the sides of the socket click into
place.
3
2
1
0
3
2
1
0
Remove in this order
Add in this order
Содержание Sun Fire V100
Страница 10: ...x Sun Fire V100 Server User s Guide December 2001 ...
Страница 17: ...PART I Installation and Configuration ...
Страница 18: ......
Страница 24: ...6 Sun Fire V100 Server User s Guide December 2001 ...
Страница 59: ...PART II Remote and Local Management ...
Страница 60: ......
Страница 82: ...64 Sun Fire V100 Server User s Guide December 2001 ...
Страница 97: ...PART III Maintenance and Troubleshooting ...
Страница 98: ......
Страница 114: ...96 Sun Fire V100 Server User s Guide December 2001 ...
Страница 130: ...112 Sun Fire V100 Server User s Guide December 2001 ...
Страница 131: ...PART IV Appendixes ...
Страница 132: ......
Страница 142: ...124 Sun Fire V100 Server User s Guide December 2001 ...
Страница 146: ...Index 128 Sun Fire V100 Server User s Guide December 2001 ...