Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
Storage Automated Diagnostic Environment Version 2.1 Agent
Functionality
The Storage Automated Diagnostic Environment version 2.1 remotely monitors Sun
network storage devices. The Storage Automated Diagnostic Environment can
monitor host message files for errors, or connect directly through the “in-band” data
path or “out-of-band” management path of Sun StorEdge devices, in order to obtain
status information about each device being monitored.
Storage Automated Diagnostic Environment Version 2.1 Diagnostic
Functionality
Diagnostic tests have been integrated into the Storage Automated Diagnostic
Environment for device diagnostics and field replaceable unit (FRU) isolation. Each
test can be run individually from the command line interface (CLI) or from the
Storage Automated Diagnostic Environment GUI.
The following tests are described in the Storage Automated Diagnostic Environment
User’s Guide, Version 2.1.
■
Sun StorEdge PCI FC-100 Host Adapter Board Test (
ifptest
)
■
Sun StorEdge PCI Dual Fibre Channel Host Adapter Board Test (
qlctest
)
■
Sun StorEdge SBus FC-100 Host Adapter Board Test (
socaltest
)
■
Sun StorEdge Network FC Switch-16 Switch Test (
switchtest
)
■
Sun StorEdge T3 and T3+ array Tests (
t3ofdg
,
t3test
,
t3volverify
)
■
Virtualization Engine Tests (
vediag
,
veluntest
)
■
Brocade Silkworm Test (
brocadetest
)
From the Storage Automated Diagnostic Environment GUI, you can select tests from
the topology or from a list view. When the tests execute, the Storage Automated
Diagnostic Environment initiates the test on the proper host. You can retrieve test
results by using the Test Manager selection from the GUI.
Running Diagnostic Tests From the GUI
If you run the diagnostic test from the Storage Automated Diagnostic Environment
home window, you can easily access test configuration, control, and results using the
buttons in the dialog boxes. The test parameter options, however, are unique for
each test and are illustrated in the individual sections with each test in this chapter.
Содержание StorEdge
Страница 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 55: ...Chapter 3 Diagnostics 37 FIGURE 3 4 Storage Automated Diagnostic Environment Test from Topology Window ...
Страница 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 131: ...Appendix B Brocade Communications Systems Switch Troubleshooting 113 FIGURE B 5 Test Result Details with Remedy Request ...
Страница 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...