102
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
5. Start Testing FRUS.
■
Storage Automated Diagnostic Environment version 2.1 tests, such as the
brocadetest
(1M),
qlctest
(1M),
t3test
(1M),
linktest
(1M), and
a5ktest(1M).
■
Brocade CLI tests (
loopPortTest
,
spinFab
,
crossPortTest
)
■
Sun StorEdge T3 Array tests, such as
T3OFDG
(1M)
■
Sun StorEdge A3500FC arrays Healthcheck
Note –
The conclusion of these tests isolate the problem to a FRU to be replaced.
Follow the appropriate hardware manual for proper FRU replacement procedures.
6. Verify the fix.
■
/var/adm/messages
(path online, multipath informational messages)
■
Storage Automated Diagnostic Environment version 2.1 status
■
Sun StorEdge Traffic Manager or VxDMP, to return the path to its normal state
Содержание StorEdge
Страница 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 55: ...Chapter 3 Diagnostics 37 FIGURE 3 4 Storage Automated Diagnostic Environment Test from Topology Window ...
Страница 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 131: ...Appendix B Brocade Communications Systems Switch Troubleshooting 113 FIGURE B 5 Test Result Details with Remedy Request ...
Страница 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...