52
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
From the messages above, it is apparent that the following events occurred:
■
The
u2ctlr
took control of LUN 0 on
t3b2
■
SSD and SCSI warnings were seen on host
diag226
■
Sun StorEdge Traffic Manager Software has degraded the paths to a device with
WWN 50020f23000003d5
■
One HBA went from CONNECTED to NOT CONNECTED
■
Port 0 on a Sun StorEdge 2 Gb FC switch (ip=172.20.67.84) went offline
... (
continuation
)
----------------------------------------------------------------------
Site : FSDE LAB Broomfield CO
Source : diag226.central.sun.com
Severity : Error (Actionable)
Category : SWITCH2 DeviceId : switch2:100000c0dd00bfda
EventType: StateChangeEvent.M.port.0
EventCode: 12.26.35
EventTime: 2002/09/13 13:06:35
DESCRIPTION: ’port.0’ in SWITCH2 sw-67-84 (ip=172.20.67.84) is now Not-
Available (state changed from ’online’ to ’offline’):
INFORMATION:
A port on the switch2 has logged out of the fabric and gone offline
RECOMMENDED-ACTION:
1. Verify cables, GBICs and connections along Fibre Channel path
2. Check SAN Topology GUI to identify failing segment of the data path
3. Verify correct FC switch2 configuration
Содержание StorEdge
Страница 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 55: ...Chapter 3 Diagnostics 37 FIGURE 3 4 Storage Automated Diagnostic Environment Test from Topology Window ...
Страница 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 131: ...Appendix B Brocade Communications Systems Switch Troubleshooting 113 FIGURE B 5 Test Result Details with Remedy Request ...
Страница 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...