Chapter 3
Installing the StorEdge S1 Enclosure
53
FIGURE 3-24
Disconnecting the DC Input Power Cable From the DC Connector
Isolating the Chassis Ground Connection (DC
Version Only)
Every StorEdge S1 storage enclosure is shipped out of the factory with the chassis
ground connected to the common output return through two screws on the power
supply at the rear of the enclosure.
▼
To Isolate the Chassis Ground Connection
1. Go to the rear of the StorEdge S1 storage enclosure and locate the two screws used
to isolate the chassis ground connection.
FIGURE 3-25
Locating the Chassis Ground Connection Screws
2. Unscrew the two chassis ground connection screws.
Chassis ground
connection screws