Chapter 7
Internal Access
7-5
d. Check that the power supply wiring is tucked inside the system to avoid
pinching the wiring when you close the system unit.
2. Detach and remove the wrist strap.
3. Grasp the unit top near the power supply (see
FIGURE 7-3
).
Rotate the unit top at a 15-degree angle and rotate your hand position so that
thumbs and fingers point up and the five interlock hooks can be aligned.
Note –
The interlock hooks do not engage until the unit is lowered to a 45-degree
angle. Continue to hold the cover with your hands.
4. Reconnect the unit top and bottom (see
FIGURE 7-3
).
a. Rest the front edges together to connect the interlock hooks by pushing gently
toward the back of the unit.
b. As you lower the unit top, continue to push back to secure the connection. The
unit top will rest slightly forward.
c. Gently push the unit top back a few millimeters until the unit top and bottom
are aligned.
5. Attach the lock block.
Attach the lock block by inserting the PEM screw through the block on the outside,
through the security loop on the inside, and into the power supply (see
FIGURE 7-3
).
Tighten the screw with a screwdriver. Be careful not to overtighten the screw.
Содержание SPARC classic X
Страница 28: ...1 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 48: ...3 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 58: ...4 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 68: ...6 6 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 114: ...9 24 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 168: ...A 4 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...