4-8
SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual • November 1993
For example, in a system using 16-Mbyte DSIMMs, if an error is detected at physical
memory address 12fe958,
TABLE 4-4
shows that the error occurred in memory bank 1
(DSIMMs U0304 and U0303).
TABLE 4-6
then shows that the defective DSIMM is in
slot U0304. Follow the instructions in Section 11.3.2 “Removing a DSIMM” on
page 11-13 for removing the defective DSIMM at that location. Then, to install the
replacement, follow the instructions in Section 11.3.3 “Replacing a DSIMM” on
page 11-15.
FIGURE 4-2
DSIMM Slot Locations
TABLE 4-4
Physical Memory Address Ranges for 4-Mbyte and 16-Mbyte SIMMs
Physical Memory Address Ranges
Bank
SIMM #
4-Mbyte SIMMs
16-Mbyte SIMMs
1
U0304
0000000 through 07FFFFF
0000000 through 1FFFFFF
1
U0303
0000000 through 07FFFFF
0000000 through 1FFFFFF
2
U0301
2000000 through 27FFFFF
2000000 through 3FFFFFF
2
U0302
2000000 through 27FFFFF
2000000 through 3FFFFFF
3
U0402
4000000 through 47FFFFF
4000000 through 5FFFFFF
3
U0401
4000000 through 47FFFFF
4000000 through 5FFFFFF
SIMM slot U0304
SIMM slot U0301
SIMM slot U0402
SIMM slot U0303
SIMM slot U0302
SIMM slot U0401
Bank 1
Bank 2
Bank 3
Bank 1
Bank 2
Bank 3
Содержание SPARC classic X
Страница 28: ...1 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 48: ...3 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 58: ...4 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 68: ...6 6 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 114: ...9 24 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Страница 168: ...A 4 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...