Chapter 4
Troubleshooting Procedures
4-9
Note –
Both DSIMMs in a memory bank have the same physical address range. The
last digit in the physical address reported determines which of the two DSIMMs in a
bank caused the memory error (see
TABLE 4-6
).
TABLE 4-5
Physical Memory Address Ranges for 1-Mbyte and 2-Mbyte SIMMs
Physical Memory Address Ranges
Bank
SIMM #
1-Mbyte SIMMs
2-Mbyte SIMMs
1
U0304
0000000 through 01FFFFF
0000000 through 01FFFFF
1
U0303
0000000 through 01FFFFF
0400000 through 05FFFFF
2
U0301
2000000 through 21FFFFF
2000000 through 21FFFFF
2
U0302
2000000 through 21FFFFF
2400000 through 25FFFFF
3
U0402
4000000 through 41FFFFF
4000000 through 41FFFFF
3
U0401
4000000 through 41FFFFF
4400000 through 45FFFFF
TABLE 4-6
Determining the Defective DSIMM
If the physical address ends in . . .
The defective DSIMM is in . . .
0, 1, 2, 3, 8, 9, A, or B
4, 5, 6, 7, C, D, E, or F
U0304, U0301, or U0402
U0303, U0302, or U0401