50
Netra 1290 Server System Administration Guide • May 2006
FIGURE 4-3
System Indicators
The indicator states are shown in
TABLE 4-4
.
TABLE 4-4
System Fault Indicator States
FRU name
Fault
indicator lit
when fault
detected
*
System
Fault
indicator lit
on FRU
fault*
Top Access
lit on FRU
fault
1
Comments
System board
Yes
Yes
Yes
Includes processors, ecache, and DIMMs.
Level 2 repeater
Yes
Yes
Yes
IB_SSC
Yes
Yes
Yes
System controller
No
Yes
Yes
IB_SSC fault LED lit.
Fan
Yes
Yes
Yes
IB fan fault LED lit.
Power supply
Yes (by
hardware)
Yes
No
All power supply indicators are lit by the
power supply hardware. There is also a
predicted fault indicator. Power supply
EEPROM errors do not cause degraded
states as there is no indicator control.
Power distribution board
No
Yes
Yes
Can only be degraded.
Backplane
No
Yes
Yes
Can only be degraded.
System indicator board
No
Yes
Yes
Can only be degraded.
System configuration
card
No
Yes
No
Fan tray
Yes
Yes
No
SERVICE REQUIRED
SYSTEM
ALARM
POWER SOURCE
Locator
System Fault
System Power
On/Standby
switch
Top Access Required
Solaris OS Running
Alarm1 and Alarm2
Source A and Source B
Содержание Netra 1290
Страница 12: ...xii Netra 1290 Server System Administration Guide May 2006...
Страница 32: ...14 Netra 1290 Server System Administration Guide May 2006...
Страница 48: ...30 Netra 1290 Server System Administration Guide May 2006...
Страница 80: ...62 Netra 1290 Server System Administration Guide May 2006...
Страница 104: ...86 Netra 1290 Server System Administration Guide May 2006...
Страница 112: ...94 Netra 1290 Server System Administration Guide May 2006...
Страница 142: ...124 Netra 1290 Server System Administration Guide May 2006...