Sun Fire X4600 to Sun Fire X4600 M2 Server Migration
27
2. Once you’ve inserted the disc in the drive, or mounted the ISO image, reboot.
You will see a menu screen. Choose “1”. The firmware update process begins and
takes about 5 minutes.
Note –
The upgrade script runs a number of programs, some of which issue
instructions. These can be ignored. Do nothing until the script finishes, and the DOS
prompt (
A:>
) appears.
Once the script has finished remove the CD from the drive or unselect the CD image
from the remote console and reboot. When prompted “Press Ctrl-C to start LSI
Configuration Utility” press that key. Verify that the LSI HBA BIOS version
information matches that on the last line of your worksheet. Then exit the utility and
reboot. The upgrade to an M2 system is complete.
CPU Modules and Memory DIMMs
“CPU Module Models” on page 27
describes the CPU module models and explains
the rules for populating the module with memory DIMMs.
“Populating a Server With CPU Modules” on page 3
describes the rules for
populating a server with CPU modules and explains how module slot letters map to
numeric module IDs.
“Locating Faulty CPUs and DIMMs” on page 39
describes the CPU modules’ built-in
diagnostic features.
CPU Module Models
This section describes the various CPU module models. Some models are available
in multiple part numbers. All part numbers within a given model share basic
features such as the kind of CPU they support and the way they use memory
DIMMs. Individual part numbers vary as to the specific CPU they support. For more
information refer to the Sun System Handbook:
http://sunsolve.sun.com/handbook_pub/
Each CPU module model description indicates whether it can be used with the
X4600 server or the X4600 M2 server. No CPU module model can be used with both
systems.
The sections that document individual CPU modules are:
Содержание Fire X4600
Страница 2: ...Please Recycle...
Страница 5: ...Contents v Locating Faulty CPUs and DIMMs 39 To Locate Faulty CPU s and DIMMs 39...
Страница 6: ...vi Server Migration August 2009...
Страница 8: ...viii Server Migration July 2009...
Страница 10: ...x Server Migration July 2009...
Страница 17: ...Sun Fire X4600 to Sun Fire X4600 M2 Server Migration 5 FIGURE 1 CPU Module Population rules and numbering...
Страница 52: ...40 Server Migration August 2009...