Sun Fire X4600 to Sun Fire X4600 M2 Server Migration
9
Note –
You must allow the entire server, not just the SP, to reboot to main power
mode to complete the password reset. This is because the state of the P20 jumper
cannot be determined without the host CPU running. Wait until the end of POST,
when you see the CMOS password cleared by jumper message, after which both the
BIOS and SP passwords are reset.
■
The ILOM SP password is reset to the default, changeme.
■
The BIOS password is removed. If you had a BIOS password set, you are no
longer prompted for one.
9. Log in to the ILOM web GUI using root as the user name and changeme as the
password.
For login instructions, refer to the
Integrated Lights Out Manager Administration Guide
,
819-1160.
10. Change the default password to a password of your choice.
11. Repeat steps 1 through 8 to remove the P20 jumper. (Remove the jumper in step 5
rather than inserting it.)
Note –
If you do not remove the P20 jumper, the ILOM SP and BIOS passwords will
be reset every time you power-cycle the server.