3-Wire Power Cord Installation
Remove the Terminal Block Access Plate on the back
of range by removing the fixing screw.
Assemble the strain relief in the hole on bracket.
Insert the power cord through the strain relief and
tighten.
Allow enough slack to easily attach the cord terminals
to the terminal block.
Remove the 3 wire terminal bolts and washers from
the terminal block.
Plug the terminal holes of power cord. The neutral or
ground wire of the power cord must be connected to
the ground terminal located at the left of the terminal
block. The power leads must be connected to the
other two terminals.
Plug washers and tighten bolts securely.
Assemble the Terminal Block Access Plate.
4-Wire Power Cord Installation
Remove the Terminal Block Access Plate on the back
of range by removing the fixing screw.
Assemble the strain relief in the hole on bracket.
Insert the power cord through the strain relief and
tighten.
Allow enough slack to easily attach the cord terminals
to the terminal block.
Remove the 3 wire terminal bolts and washers from
the terminal block.
Remove the ground wiring of the range from the
neutral terminal at the left of the terminal block.
Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to
the neutral terminal located at the left of the terminal block. The ground wires of the power supply
cord and the range must be attached to the frame of range by using the green-colored grounding
screw. The power leads must be connected to the other two terminals.
Plug washers and tighten bolts securely.
Assemble the Terminal Block Access Plate.
LEVELING THE RANGE
The range must be level to obtain proper operation. The four screw-
type leveling legs located on the corners at the bottom of range should
be adjusted by turning them clockwise to make the range higher or
counter-clockwise to lower the range until the range is level. Use a
level on surface units to check the leveling of the range.