4
5
SPECIFICATIONS HEAT RECOVERY VENTILATORS PERFORMANCE RATINGS
ENERGY PERFORMANCE
SUPPLY
TEMPERATURE
NET
AIR FLOW
SUPPLY/
EXHAUST
FLOW RATIO
AVERAGE
POWER
(WATTS)
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
NET
MOISTURE
TRANSFER
°C
°F
L/S CFM
HEA
TING
i
0
32
33
70
0.92
60
65
80
0.07
ii
0
32
45
96
1.00
94
61
70
0.01
iii
0
32
55
117
.99
94
60
68
-0.01
iv
v
-25
-13
30
64
0.94
71
60
76
0.07
MODEL: SHRV150DM
Options Installed:
None
Electrical:
120 V - 1.5 Amp
Exhaust Air Transfer Ratio:
0.02
Low Temp. Reduction Reduction During -25°C Test 20.0%
maximum Unbalanced Airflow During -25°C Test: 8.5 L/s
19 3/4 IN.
Net Supply
Net Exhaust
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
GROSS AIR FLOW
POWER
PRESSURE
AIR FLOW
SUPPLY
EXHUAST
Pa
in. wg
L/S
CFM
L/S
CFM
L/S
CFM WATTS
25
0.1
67
143
70
149
70
149
116
50
0.2
62
132
65
137
64
136
115
75
0.3
56
118
58
123
59
125
115
100
0.4
49
104
51
108
54
113
114
125
0.5
43
91
45
95
47
100
113
150
0.6
38
80
40
84
41
86
112
175
0.7
34
72
35
75
33
71
111
200
0.8
30
63
31
66
27
57
110
225
0.9
25
52
25
54
22
47
109
SUMMERAIRE MFG., PETERBOROUGH, ONTARIO K9J 6X6
Home Ventilating Institute
12 1/2 IN
STALE AIR
TO
OUTSIDE
FRESH AIR
TO
HOUSE
STALE AIR
FROM
HOUSE
FRESH AIR
FROM
OUTSIDE
24 1/8 IN.
Ext. Differential Pressure - Pascals
300
275
250
225
200
175
150
125
100
75
50
25
0
Gross Airflow - L/s
10 20 30 40 50 60 70 80 90
Содержание Proventor II Series
Страница 2: ...2 ...