22
23
HR
V
TROUBLE SHOOTING GUIDE
OPERA
TION GUIDE
PROBLEM
PROBABLE CAUSE
SOLUTION
HUMIDITY
T
OO HIGH
HR
V
AIR FLOWS IMPROPERL
Y BALANCED
BALANCE HR
V
HR
V UNDERSIZED
DEHUMIDIST
AT
SET
T
OO HIGH
SET
DEHUMIDIST
AT
T
O
A LOWER SETTING.
HR
V UNDERSIZED
TO HANDLE HOT
TUB,
INDOOR POOLS, ETC.
COVER POOLS, HOT
TUBS ETC.
WHEN NOT
IN USE.
LIFESTYLES OF OCCUP
ANTS
AVOID HANGING CLOTHES
TO DR
Y INSIDE,
AVOID ST
ORING
WOOD INSIDE
AND
VENT
DR
YERS OUTSIDE.
20 MINUTE
TIMERS DO NOT
WORK
WIRED INCORRECTL
Y
CHECK LED
AT
HR
V, IF BLINKING RED,
WIRING IS INCORRECT
,
CHECK
WIRING.
HR
V
AND/OR DUCTS FROSTING UP
HR
V
AIR FLOWS IMPROPERL
Y BALANCED
BALANCE HR
V
NOTE: FROST
BUILD UP
IS EXPECTED ON
CORES PRIOR
TO INITIA
TING
A DEFROST
CYCLE.
SUPPL
Y
AIR FEELS COOL
HR
V
AIR FLOWS IMPROPERL
Y BALANCED.
BALANCE HR
V.
POOR LOCA
TION OF SUPPL
Y GRILLS.
LOCA
TE GRILLS HIGH ON
W
ALLS OR
UNDER BASEBOARDS.
OUTDOOR
TEMPERA
TURE
EXTREMEL
Y COLD.
IF SUPPL
Y
AIR IS INST
ALLED INT
O RETURN
AIR OF FURNACE, FURNACE F
AN NEEDS
TO RUN CONST
ANTL
Y
TO DISTRIBUTE
VENTILA
TION
AIR COMFOR
TABL
Y.
ENSURE
THA
T
A BREA
THER “T” IS
INST
ALLED IN SUPPL
Y DUCT
.
PREHEA
TER MA
Y BE REQUIRED.
W
ATER IN BOTT
OM OF HR
V
DRAIN P
AN (S) PLUGGED
ENSURE “O” RINGS ON DRAIN SPIGOT
SEA
TS PROPERL
Y
LOOK FOR KINKS IN LINE.
DRAIN LINES OBSTRUCTED
CHECK
W
ATER DRAIN CONNECTIONS.
MAKE SURE
W
ATER DRAINS PROPERL
Y
FROM
THE P
AN(S)
HR
V HEA
T EXCHANGE CORE NOT
INST
ALLED PROPERL
Y
CHECK ORIENT
ATION LABEL
ON FRONT
OF
CORE
AND POSITION CORE CORRECTL
Y.
HR
V MA
Y NOT
BE LEVEL
Содержание Proventor II Series
Страница 2: ...2 ...