![Sumitomo TYPE-72M12 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/sumitomo/type-72m12/type-72m12_manual-to-operation_1390674052.webp)
2-26
2. Basic splicing operation
|
Drop cable splicing
2. Basic splicing operation
1: Load the cable with its
sheath removed in the fiber
holder. Make sure that the
cable sheath touches the
groove.
Close the bigger lid of the
holder first, and then close
the smaller lid.
2: Remove the fiber coating at
2~4mm away from the edge
of the fiber holder. (Touch
the JR-M03 against the edge
to remove, and you can
remove the coating at 3mm
away from the edge.)
3: Clean the bare fiber from
the end of the fiber coating
with a gauze pad moistened
with pure alcohol. Pull the
bare fiber through the gauze
pad and rotate the fiber to
remove any coating residue.
5: Repeat step 1~4 for the
other cable.
4: Place the fiber holder in the
cleaver, touching the edge of
the fiber holder against the
edge of the fiber holder
receptacle. Cleave the fiber
referring to the cleaver
instructions.
6: Place the fiber holder in
the splicer
and start the
splicing process.
(Note: Perform an arc test
prior to splicing.)
●
Fiber preparation procedures