6
2
Electrical check
2.1
Pump start and cable check
c
DANGER! Always check that the pump
is disconnected from the electric
power supply before opening any part
of the pump.
□
Check if the pump starts by connecting it to the power
supply.
□
Check the direction of rotation, it should make a jerk
in the direction of the arrow on the pump (anti-clock-
wise). To change direction of rotation shift two phases.
(Figure 1)
□
Check the cable for damage and that there is no wa-
ter or corrosion in the connecting plug.
□
Test the insulation between cable end / plug and
earth.
Note!
DO NOT MEGGER 1000V PUMPS WITH
GROUND CHECK DIODE (GC) CONNECTED.
2.2
Dismantling cover
Unscrew the cap nuts/screws for the cover. Lift off
the cover and disconnect the power cables from the
contactor/terminal block. If the water has penetrated
through the cable gland, the cable seal should be re-
placed. Remove strain relief clamp prior to unscrewing
cable gland body. Pull out cable, cable seal and wash-
ers. (Figure 2-4)
Figure 1: Direction of rotation
Im
pe
lle
r ro
tation
Sta
rt r
ea
ct
io
n
Figure 2: Pump with contactor/terminal block/SoftDrive
(J 205)
Figure 3: Pump with contactor/terminal block (J 405)
Figure 4: Pump with terminal block (J 604)
Содержание J 205
Страница 1: ...en www sulzer com Submersible Drainage Pump J 205 J 405 J 604 Workshop Manual 00831887 02 2020 ...
Страница 30: ...30 11 Sectional drawing Tools J 205 ...
Страница 31: ...31 J 405 ...
Страница 32: ...32 J 604 ...
Страница 37: ...37 ...