25
10.4
J 205/J 405 three phase Direct Start D.O.L. with terminal block (6-leads stator)
The stators are wound for different voltages/frequencies and can be Delta- or Star-connected. For example
stator 400/690V 50Hz is Delta-connected for 400V duty and 578/1000V is Star-connected for 1000V duty.
(Figure 52, 53)
10.5
J 205/J 405 three phase Star Delta starting with terminal block (6-leads stator)
The stators are wound for different voltages/frequencies For example stator 400/690V 50Hz is Delta connect
-
ed for 400V duty. The Star delta starting is obtained by using a separate starter. (Figure 55)
351183AD
Figure 52: Delta connected winding D.O.L.
351182AD
Figure 53: Star connected winding D.O.L.
Star/Delta-star t or
Direct star t D
351184AC
Figure 54: Connection for Star Delta Start with 2x power
cable including 3-core control cable
Содержание J 205