User Manual | US-EN
COALESCING FILTERS
30
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
The direction of flow for the filter must be observed during installation. This must match the direction of flow for the
pipeline.
Direction of flow
left » right (factory default)
Direction of flow
Right » left
1
2
3
2
1
3
The housing head and housing body use a double trapezoidal thread. The direction of flow through the filter can be
adjusted to that of the pipeline by turning the housing head 180°. The direction of flow is indicated via arrows [2] and
a raised marking [3] on the housing head. This must be aligned as shown. The safety runner [1] must always be easily
accessible on the front side.
For maintenance and repair work, it is recommended to install a bypass line [4] and shut-off valve [5].
4
5
1. Attach sealing material, e.g. PTFE band (EN 837-2) to the pipe ends
2. Screw pipe thread into the filter inlet until the connection is solid and sealed
3. Screw pipe thread into the filter outlet until the connection is solid and sealed
After completing assembly work, check to ensure the housing body is screwed in correctly, the safety runner is pushed
up and the locking screw is hand-tightened. Complete a leak test to check installation work. For more information, see
“9.6 Leak test” on page 41.