11. Disassembly
11.1 Warning
DANGER
Use of incorrect accessories, materials or replacement parts!
The use of incorrect replacement parts, accessories or installation material or operating and
auxiliary materials may result in death or severe injuries. This may also cause functional or
operating disruptions or material damage.
• Only use undamaged original parts, auxiliary and operating materials for all disassembly
work as indicated by the manufacturer.
• Only use fittings and connection elements permitted for the specific application and suitable
tools in proper condition.
DANGER
Compressed air
The risk of death or severe injuries exists in case of contact with fast or sudden exiting
compressed air or due to bursting system parts.
• Only work on the system when it is depressurized and secure the system against unintended
restart.
• Set up a safety zone around the system when carrying out any assembly, installation,
maintenance and repair work.
• Before pressurizing the system, check and tighten all pipe connections.
• Pressurize the system slowly.
• Avoid pressure surges and high pressure differentials.
• Install all pipelines without mechanical tension. Avoid vibrations occurring in the pipeline
network by using vibration dampers.
• Carefully observe the installation and operating instructions in this manual.
• Carefully observe inspection and maintenance intervals.
• Permanently install inlet and outlet lines.
• Do not make modifications on the product.
WARNING
Insufficient qualification!
If personnel have insufficient qualifications, this may result in accidents, personal injury and
property damage as well as operating disruptions while working on the product.
The work on the product described in the following may only be carried out by compressed
technology technicians and must be documented.