User Manual | US-EN
COALESCING FILTERS
34
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
9.4 Exchange the float drain
The following requirements must be fulfilled to exchange the float drain and preparatory work must be completed.
Preconditions
Tool
Material
Protective equipment
• Screwdriver - Phillip's head size
0.10 inch (2.5 mm)
• New float drain with included
adapter
•
Protective gloves (liquid-
resistant)
•
Safety glasses with side
protection (goggles)
•
Hearing protection
•
Class FFP 3 respirator
•
Safety shoes
Preparatory work
1.
Open any bypass lines
Picture
Description
1.
1.
1. Close the shut-off valves upstream and downstream of
the filter or relevant system section
2.
2. Turn the knurled-head screw on the float drain
counter-clockwise (left) from >>automatic drainage<<
to >>mechanically open<<
Automatic drain
Mechanically open