Section 1
SAFETY
2
death or serious injury may result.
1.4 FIRE AND EXPLOSION
A.
Clean up spills of lubricant or other combustible
substances immediately, if such spills occur.
B.
Shut off the compressor and allow it to cool.
Then keep sparks, flames and other sources of
ignition away and
DO NOT
permit smoking in the
vicinity when checking or adding lubricant or when
refilling air line anti-icer systems with antifreeze
compound.
C. DO NOT
permit fluids, including air line anti-icer
system antifreeze compound or fluid film, to accu-
mulate on, under or around acoustical material, or
on any external surfaces of the air compressor.
Wipe down using an aqueous industrial cleaner or
steam clean as required. If necessary, remove
acoustical material, clean all surfaces and then
replace acoustical material. Any acoustical material
with a protective covering that has been torn or
punctured should be replaced immediately to pre-
vent accumulation of liquids or fluid film within the
material.
DO NOT
use flammable solvents for
cleaning purposes.
D.
Disconnect and lock out all power at source prior
to attempting any repairs or cleaning of the com-
pressor or of the inside of the enclosure, if any.
E.
Keep electrical wiring, including all terminals and
pressure connectors in good condition. Replace
any wiring that has cracked, cut, abraded or other-
wise degraded insulation, or terminals that are
worn, discolored or corroded. Keep all terminals
and pressure connectors clean and tight.
F.
Keep grounded and/or conductive objects such
as tools away from exposed live electrical parts
such as terminals to avoid arcing which might serve
as a source of ignition.
G.
Remove any acoustical material or other materi-
al that may be damaged by heat or that may sup-
port combustion and is in close proximity, prior to
attempting weld repairs.
H.
Keep suitable fully charged Class BC or ABC fire
extinguisher or extinguishers nearby when servic-
ing and operating the compressor.
I.
Keep oily rags, trash, leaves, litter or other com-
bustibles out of and away from the compressor.
J. DO NOT
operate the compressor without proper
flow of cooling air or water or with inadequate flow
of lubricant or with degraded lubricant.
K. DO NOT
attempt to operate the compressor in
any classification of hazardous
environment unless the compressor has been spe-
cially designed and manufactured for that duty.
1.5 MOVING PARTS
A.
Keep hands, arms and other parts of the body
and also clothing away from couplings, fans and
other moving parts.
B. DO NOT
attempt to operate the compressor with
the fan, coupling or other guards removed.
C.
Wear snug-fitting clothing and confine long hair
when working around this compressor, especially
when exposed to hot or moving parts.
D.
Keep access doors, if any, closed except when
making repairs or adjustments.
E.
Make sure all personnel are out of and/or clear
of the compressor prior to attempting to start or
operate it.
F.
Disconnect and lock out all power at source and
verify at the compressor that all circuits are de-
energized to minimize the possibility of accidental
start-up, or operation, prior to attempting repairs or
adjustments. This is especially important when
compressors are remotely controlled.
G.
Keep hands, feet, floors, controls and walking
surfaces clean and free of fluid, water or other liq-
uids to minimize the possibility of slips and falls.
1.6 HOT SURFACES, SHARP EDGES AND SHARP
CORNERS
A.
Avoid bodily contact with hot fluid, hot coolant,
hot surfaces and sharp edges and corners.
B.
Keep all parts of the body away from all points of
air discharge.
C.
Wear personal protective equipment including
gloves and head covering when working in, on or
around the compressor.
D.
Keep a first aid kit handy. Seek medical assis-
tance promptly in case of injury.
DO NOT
ignore
small cuts and burns as they may lead to infection.
1.7 TOXIC AND IRRITATING SUBSTANCES
A. DO NOT
use air from this compressor for respi-
ration (breathing) except in full compliance with
OSHA Standards 29 CFR 1910 and/or any applica-
ble Federal, State or Local codes or regulations.
Death or serious injury can result from inhaling
compressed air without using proper safety
equipment. See OSHA standards and/or any
applicable Federal, State, and Local codes, stan-
dards and regulations on safety equipment.
Содержание LS16T
Страница 6: ......
Страница 23: ...Section 2 DESCRIPTION 17 Figure 2 4A Control System Diagram Functional Components...
Страница 24: ...Section 2 DESCRIPTION 18 Figure 2 4B Control System Diagram START...
Страница 25: ...Section 2 DESCRIPTION 19 Figure 2 4C Control System Diagram MODULATION...
Страница 26: ...Section 2 DESCRIPTION 20 Figure 2 4D Control System Diagram FULL LOAD...
Страница 27: ...Section 2 DESCRIPTION 21 Figure 2 4E Control System Diagram UNLOAD...
Страница 32: ...NOTES 26...
Страница 35: ...Section 3 SPECIFICATIONS 29 Figure 3 2 Identification LS16T 100 125 Air cooled 02250138 172R01...
Страница 36: ...Section 3 SPECIFICATIONS 30 Figure 3 3 Identification LS16T 150 200 Air cooled 02250134 200R02...
Страница 44: ...NOTES 38...
Страница 54: ...NOTES 48...
Страница 57: ...NOTES 51...
Страница 58: ...Section 8 ILLUSTRATIONS AND PARTS LIST 52 02250134 194R00 8 3 MOTOR FRAME COMPRESSOR AND PARTS 100 125HP...
Страница 60: ...Section 8 ILLUSTRATIONS AND PARTS LIST 54 02250134 195R00 8 4 MOTOR FRAME COMPRESSOR AND PARTS 150 200HP...
Страница 62: ...Section 8 ILLUSTRATIONS AND PARTS LIST 56 02250134 187R00 8 5 AIR INLET SYSTEM...
Страница 64: ...Section 8 ILLUSTRATIONS AND PARTS LIST 58 02250138 173R00 8 6 FLUID COOLING SYSTEM 100 125HP AIR COOLED...
Страница 66: ...Section 8 ILLUSTRATIONS AND PARTS LIST 60 02250134 189R00 8 7 FLUID COOLING SYSTEM 150 200HP AIR COOLED...
Страница 68: ...Section 8 ILLUSTRATIONS AND PARTS LIST 62 02250138 174R00 8 8 AIR PIPING SYSTEM 100 125HP AIR COOLED...
Страница 70: ...Section 8 ILLUSTRATIONS AND PARTS LIST 64 02250138 174R00 8 8 AIR PIPING SYSTEM 100 125HP AIR COOLED...
Страница 72: ...Section 8 ILLUSTRATIONS AND PARTS LIST 66 02250134 191R00 8 9 AIR PIPING SYTEM 150 200HP...
Страница 74: ...Section 8 ILLUSTRATIONS AND PARTS LIST 68 02250134 191R00 8 9 AIR PIPING SYTEM 150 200HP...
Страница 76: ...Section 8 ILLUSTRATIONS AND PARTS LIST 70 02250138 175R01 8 10 FLUID PIPING SYSTEM 100 125HP...
Страница 78: ...Section 8 ILLUSTRATIONS AND PARTS LIST 72 02250134 199R00 8 11 FLUID PIPING SYSTEM 150 200HP WATER COOLED...
Страница 80: ...Section 8 ILLUSTRATIONS AND PARTS LIST 74 02250134 197R00 8 12 DISCHARGE SYSTEM...
Страница 82: ...Section 8 ILLUSTRATIONS AND PARTS LIST 76 02250134 197R00 8 12 DISCHARGE SYSTEM...
Страница 84: ...Section 8 ILLUSTRATIONS AND PARTS LIST 78 02250134 197R00 8 12 DISCHARGE SYSTEM...
Страница 86: ...Section 8 ILLUSTRATIONS AND PARTS LIST 80 02250134 196R00 8 13 CONTROL START SYSTEM...
Страница 88: ...Section 8 ILLUSTRATIONS AND PARTS LIST 82 02250134 196R00 8 13 CONTROL START SYSTEM...
Страница 90: ...Section 8 ILLUSTRATIONS AND PARTS LIST 84 02250137 724R02 8 14 CONTROL PANEL...
Страница 92: ...Section 8 ILLUSTRATIONS AND PARTS LIST 86 02250138 176R00 8 15 ENCLOSURE 100 125HP...
Страница 94: ...Section 8 ILLUSTRATIONS AND PARTS LIST 88 02250134 193R00 8 16 ENCLOSURE 150 200HP...
Страница 96: ...Section 8 ILLUSTRATIONS AND PARTS LIST 90 8 17 DECAL GROUP...
Страница 98: ...Section 8 ILLUSTRATIONS AND PARTS LIST 92 8 17 DECAL GROUP...
Страница 100: ...Section 8 ILLUSTRATIONS AND PARTS LIST 94 8 17 DECAL GROUP...
Страница 102: ...Section 8 ILLUSTRATIONS AND PARTS LIST 96 8 18 DECAL LOCATIONS OPEN AIR COOLED...
Страница 104: ...Section 8 ILLUSTRATIONS AND PARTS LIST 98 8 19 ENCLOSURE DECALS...
Страница 106: ...Section 8 ILLUSTRATIONS AND PARTS LIST 100 8 20 DECAL LOCATIONS CONTROL BOX...
Страница 108: ...Section 8 ILLUSTRATIONS AND PARTS LIST 102 8 21 WIRING DIAGRAM LS16T AIR COOLED SUPERVISOR II DELUXE 02250138 816R01...
Страница 109: ...Section 8 ILLUSTRATIONS AND PARTS LIST 103 8 22 WIRING DIAGRAM LS16T AIR COOLED SSRV VFD COOLING FAN 02250135 132R02...
Страница 110: ...NOTES 104...
Страница 111: ......