background image

Section 2

DESCRIPTION

6

filter. There will be no problem in gaining access to

any components in the event they require service.

2.3 SULLAIR COMPRESSOR UNIT, FUNCTIONAL

DESCRIPTION

The compressor unit supplied with your compressor

is a 2--stage, positive displacement, flood lubri-

cated--type rotary screw air compressor.

As the rotors turn, air is drawn into the compressor

unit at the first stage inlet. At the outlet of the first

stage the air is compressed and discharged into the

second stage where it is recompressed to obtain a

higher pressure.

Lubricating fluid is injected into the compressor unit

at each stage and mixes directly with the air as the

rotors turn, compressing the air. The fluid flow has

three basic functions:
1. As coolant, it controls the rise of air temperature

normally associated with the heat of compres-

sion.

2. It seals the leakage paths between the rotors as

well as between the rotors and stators.

3. It acts as a lubricating film between the rotors al-

lowing the male rotors to directly drive the female

rotors (which are idlers).

After the air has been compressed in both stages of

the compressor unit, it is discharged in the form of

an air/fluid mixture. This mixture is routed through

the discharge system where the fluid is separated

from the air. At this time, the air flows to your service

line and the fluid is directed through the cooling and

lubrication system in preparation for reinjection.

2.4 COMPRESSOR COOLING AND LUBRICATION

SYSTEM, FUNCTIONAL DESCRIPTION

Ref er t o F igur es 

2 -- 2

 and 

2 -- 3

. T he c om pr es s or c ool-

ing and lubrication system is designed to provide ad-

equate lubrication as well as maintain the proper op-

erating temperature of the compressor. The system

is comprised of a finned tube exchanger, main line

filter, extra--fine bearing lube filter, thermal valve,

fluid stop valve and interconnecting piping.

Fluid is used in the system as a coolant and lubricant

and is housed in the receiver/sump (from this time

forward, the receiver sump will be referred to as the

sump). Fluid circulation is achieved by forcing the

fluid from the higher pressure area of the sump to

lower pressure regions at the compressor unit.

Fluid flows from the bottom of the receiver/sump to

the thermal valve. The thermal valve is fully open

when the fluid temperature is below 220

_

F (155

_

C).

The fluid passes through the thermal valve, the main

filter and directly to the compressor unit where it lu-

bricates, cools and seals the rotors and the com-

pression chamber.

After the fluid passes through the thermal valve, it is

then directed through the fluid filter. There the fluid is

filtered in preparation for injection into the compres-

sion chambers. This filter has a cleanable element

and built--in bypass which allow some fluid to flow

even when the filter becomes plugged and requires

changing, or when the viscosity of the fluid is too

high for adequate flow. After the fluid is properly fil-

tered, it then flows to the fluid stop valve and on to

the bearing filter.
The fluid stop valve prevents the fluid from filling the

compressor unit when it is shut down. When the

compressor is in operation, the fluid stop valve is

held open by air pressure from the compressor unit

allowing a free flow of fluid from the sump back to the

compressor unit. On shutdown, the compressor unit

pressure is reduced causing the fluid stop valve to

close and isolate the unit from the cooling system.

The fluid stop valve pilot valve also opens to assist in

relieving the stop valve pilot signal pressure and

shutdown.
A portion of the fluid flowing to the compressor is

routed to the anti--friction bearings which support

the rotors inside the compressor unit. Prior to enter-

ing the compressor unit, this fluid is taken through

an extra--fine bearing filter, thus assuring properly

filtered fluid for bearing supply.
The bearing filter has a replacement element and an

integral pressure bypass valve. An associated ser-

vice indicator shows red when the filter needs ser-

vicing. This indicator has a pressure setting lower

than that of the bypass valve. After the initial 50 hour

filter change, the indicator will rarely show red under

normal operating conditions.

2.5 COMPRESSOR DISCHARGE SYSTEM, FUNC-

TIONAL DESCRIPTION

Ref er t o F igur e 

2 -- 3

 and 

2 -- 4

. T he S ullair c om pr es -

sor unit discharges the compressed air/fluid mixture

through a discharge check valve into the combina-

tion receiver/sump. The discharge check valve pre-

vents air in the sump from returning to the compres-

sion chamber after the compressor has been shut

down. The receiver has three basic functions:
1. It acts as a primary fluid separator.

2. It serves as the compressor fluid sump.

3. It houses the final fluid separator element.
The compressed air/fluid mixture enters the receiv-

er and is directed against the wall of the tank. By

change of direction and impingement action, the

larger droplets of fluid fall to the bottom of the sump.

The fractional percentage of fluid remaining in the

compressed air collects on the surface of the final

separator element as the air flows through the sepa-

rator. As more and more fluid collects on the surface

of the element, the fluid descends to the bottom of

the separator, where the return line (scavenge tube)

leads from the bottom of the separator element to

the compressor unit. Fluid collected at the bottom of

the element is returned to the compressor unit by a

pressure difference between the area surrounding

the separator element and the compressor. An ori-

Содержание 20/12 500 CFM

Страница 1: ...Operator s Manual and Parts List Industrial Rotary Screw Air Compressor Part Number 253497 eSullair Corporation 20 12 200 400HP Air Cooled...

Страница 2: ...t Sullair s corporate headquarters in Michigan City Indiana Instruction includes discussion of the function and installation of Sullair service parts troubleshooting of the most common problems and ac...

Страница 3: ...TIONAL DESCRIPTION 6 2 5 COMPRESSOR DISCHARGE SYSTEM FUNCTIONAL DESCRIPTION 9 2 6 CAPACITY CONTROL SYSTEM FUNCTIONAL DESCRIPTION 12 2 7 AIR INLET SYSTEM FUNCTIONAL DESCRIPTION 12 2 8 INSTRUMENT PANEL...

Страница 4: ...NT 25 PRESSURE REGULATOR VALVE MAINTENANCE 26 FLUID STOP VALVE 26 CONTROL PRESSURE REGULATOR VALVE 27 RUNNING BLOWDOWN VALVE MAINTENANCE 28 THERMAL VALVE 28 MINIMUM PRESSURE CHECK VALVE MAINTENANCE 29...

Страница 5: ...the compressor or at any other point along the air line when an air hose exceeding 1 2 inside diameter is to be connected to the shut off throttle valve to reduce pressure in case of hose failure per...

Страница 6: ...und this compressor especially when exposed to hot or moving parts D Keep access doors if any closed except when making repairs or adjustments E Make sure all personnel are out of and or clear of the...

Страница 7: ...onductors 1 9 LIFTING A If the compressor is provided with a lifting bail then lift by the bail provided If no bail is provided then lift by sling Compressors to be air lifted by heli copter must not...

Страница 8: ...enter it to perform service adjustments inform other per sonnel before doing so or else secure and tag the access door in the open position to avoid the possi bility of others closing and possibly lat...

Страница 9: ...erence to the guidelines and procedure operator s will be able to keep the compressor in top operational condition 2 2 DESCRIPTION OF COMPONENTS Refer to Figure 2 1 The components of the Sullair 2 sta...

Страница 10: ...into the compres sion chambers This filter has a cleanable element and built in bypass which allow some fluid to flow even when the filter becomes plugged and requires changing or when the viscosity...

Страница 11: ...the dis charge temperature reaches 265_F 130_C on first stage or 265_F 130_C on second stage All Sullair compressor models are equipped with a high pressure shutdown switch to shut down the compresso...

Страница 12: ...Section 2 DESCRIPTION 8 Figure 2 3 Piping and Instrumentation...

Страница 13: ...nation purposes this de scription will apply to compressors with an operating pressure range of 340 to 360 PSIG 2344 to 2482kPa A compressor with any other pressure range would operate in the same man...

Страница 14: ...Section 2 DESCRIPTION 10 Figure 2 5 Capacity Control System Typical...

Страница 15: ...rical power to the solenoid type pilot valve At this time the pilot valve allows dry sump tank air pressure to be ap plied directly to the Sullicon Control keeping the but terfly valve closed Simultan...

Страница 16: ...wer and runindi cators an hourmeter plus various optional fault in dicator lights see Figure 2 7 Refer to Figure 2 3 for functional locations of the fol lowing indicators and controls S The line termi...

Страница 17: ...0 Cycles Size See Model Series above Speed 1200 RPM and 1800 RPM 3 2 LUBRICATION GUIDE Sullair standard compressors are filled with Sullube 32 fluid as factory fill MIXING OF OTHER FLUIDS WITHIN THE C...

Страница 18: ...14 NOTES...

Страница 19: ...ION CHECK After the electrical wiring has been done it is neces sary to check the direction of the motor rotation This can be done by jogging the START and STOP but tons on the instrument panel When l...

Страница 20: ...16 NOTES...

Страница 21: ...ilter element change is INDICATOR required Shows red when the pressure drop through the filter is excessive SEPARATOR MAINTENANCE INDICATOR Indicates when separator element change is required Shows re...

Страница 22: ...the inlet butterfly valve when the compressor reaches maximum operating pres sure BLOWDOWN VALVE Vents sump pressure to the atmosphere during unload conditions and shutdown PRESSURE SWITCH Senses ser...

Страница 23: ...ts are nec essary see Control System Adjustments in the Maintenance Section of the manual 7 Observe the operating temperature If the operat ing temperature exceeds 230_F 129_C the cooling system or in...

Страница 24: ...20 NOTES...

Страница 25: ...owing mainte nance operations to prevent unnecessary problems 1 Clean the return line strainer 2 Clean the return line orifice 3 Clean the compressor unit gear housing bearing and shaft seal orifices...

Страница 26: ...freely in canister 3 Remove filter element and gasket seal ring and discard 4 Install new fluid filter element in canister and install the gasket seal ring to the canister flange 5 Before reinstallin...

Страница 27: ...resuming operation PRIMARY ELEMENT REPLACEMENT 1 Place the element in position on the cover and re place the lockring to secure the cover and ele ment 2 Install the cover element assembly and replace...

Страница 28: ...hes the desired pressure the pres sure switch contacts should open If the pressure switch contacts do not open or they open prior to the desired pressure the pressure switch setting will re quire adju...

Страница 29: ...ressure plate nut and disassemble the pressure plate diaphragm dia phragm gasket rubberized asbestos seat disc and seat gasket 6 Remove and discard the seat ring 7 The next step is to reassemble the r...

Страница 30: ...replace the spring as it was prior to dis assembly 16 Place the spring over the spring button as shown 17 With all parts in order replace the spring chamber and tighten 18 Tighten the adjusting screw...

Страница 31: ...all the two 2 seals one into the cover and the other onto the piston rod guide 20 Place cylinder over pilot guide 21 Replace the cover and the four 4 nuts onto the cover Tighten nuts alternately at op...

Страница 32: ...50001 456 maintenance order the following Sull air parts one 1 quad ring P N 046425 one 1 gasket P N 049812 and if necessary thermal ele ment P N 250001 349 Follow the procedure ex plained below for i...

Страница 33: ...ARNING Turn off all power relieve the pressure and discon nect coil lead wire to the valve before making re pairs It is necessary to remove the valve from the pipe line for repairs PILOT VALVE DISASSE...

Страница 34: ...ing careful attention to exploded view provided for identification and placement of parts 2 Lubricate all gaskets with Dow Corning s Valve Seal silicone lubricant or equivalent high grade sil icone gr...

Страница 35: ...systematically ana lyzed before undertaking any repairs or component replacement procedures A detailed visual inspection is worth performing for almost all problems and may avoid unnecessary addition...

Страница 36: ...ring filter element COMPRESSOR WILL NOT BUILD UP FULL DISCHARGE PRESSURE Air Demand is Too Great Check service lines for leaks or open valves Dirty Air Filter Check the filter indicator and change or...

Страница 37: ...ections and compo nents PRESSURE RELIEF VALVE OPENS REPEATEDLY High Pressure Shutdown Switch is Defective or Out of Adjustment Readjust below pressure relief valve setting or replace Defective Pressur...

Страница 38: ...34 NOTES...

Страница 39: ...630 CFM 046968 primary 1 replacement element for air filter 046956 500 630 CFM 046981 secondary 1 replacement element for air filter 046020 750 CFM 046299 primary 1 replacement element for air filter...

Страница 40: ...Section 7 ILLUSTRATIONS AND PARTS LIST 36 7 3 MOTOR FRAME COMPRESSOR AND PARTS...

Страница 41: ...1 6 hub compressor 200HP thru 350HP 047141 1 S hub compressor 400HP 250006 266 1 7 adapter 026974 1 8 compressor unit I 1 I There is an exchange program whereby a remanufactured compressor unit can be...

Страница 42: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 4 AIR INLET SYSTEM...

Страница 43: ...se hump 7 041917 1 13 capscrew hex gr5 5 16 18 x 11 2 828605 150 1 14 nut hex 3 8 16 824206 337 4 15 support air inlet filter 250000 826 1 16 capscrew hex gr5 3 8 16 x 1 828606 100 4 17 band mounting...

Страница 44: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 5 COOLING AND LUBRICATION SYSTEM...

Страница 45: ...22224 135 1 14 valve thermal I 250001 456 1 15 valve fluid stop II 250038 489 1 16 union pipe 2 805730 080 1 17 tee pipe 11 2 806630 060 1 18 nipple pipe 11 2 x 9 822224 090 1 19 nipple pipe 11 2 x 31...

Страница 46: ...Section 7 ILLUSTRATIONS AND PARTS LIST 42 7 6 COOLER ASSEMBLY...

Страница 47: ...1 6 aftercooler 200HP thru 300HP 250008 938 1 S aftercooler 350HP thru 400HP 406722 1 7 angle aftercooler support 250020 737 4 8 panel cooler side right hand 250020 739 1 9 panel Venturi 42 200HP thr...

Страница 48: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 7 DISCHARGE SYSTEM...

Страница 49: ...45626 1 18 elbow pipe 90_ 3 806530 120 2 19 nipple half 3 x 10 822448 100 1 20 coupling flexible 3 046817 1 21 nipple half 3 x 8 822448 080 1 22 nipple pipe 3 x 17 822248 170 1 23 valve disch check 21...

Страница 50: ...Section 7 ILLUSTRATIONS AND PARTS LIST 46 7 7 DISCHARGE SYSTEM...

Страница 51: ...o 3 4 250006 639 1 37 connector tube m 1 4 x 1 4 810204 025 4 38 glass sight 046559 1 39 orifice 022033 1 40 nipple pipe 1 4 x close 822204 000 2 41 strainer y line 1 4 IV 240686 1 42 rod threaded 3 4...

Страница 52: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 INSTRUMENT PANEL AND PARTS...

Страница 53: ...essure 042148 1 7 fastener suregrip 041516 4 8 nameplate Sullair 040052 1 9 capscrew hex gr5 3 8 16 x 11 2 828606 150 4 10 washer springlock 3 8 837606 125 8 11 isolator vibration 040091 4 12 nut hex...

Страница 54: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 9 CONTROL SYSTEM...

Страница 55: ...0038 666 1 19 valve solenoid 3 way V 407390 1 20 rod end spherical 5 16 left hand 042004 1 21 rod Sullicon Control 250028 170 1 22 cylinder air control VI 250016 990 1 23 rod end spherical 5 16 right...

Страница 56: ...Section 7 ILLUSTRATIONS AND PARTS LIST 52 7 9 CONTROL SYSTEM...

Страница 57: ...0094 1 35 seal cup 042538 1 36 diaphragm Sullicon 250020 028 1 37 spring control 250006 526 1 38 bolt adjusting Sullicon spring 250009 134 1 39 washer back up 021172 1 40 screw sealing 1 4 28 x 3 4 04...

Страница 58: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 ELECTRIC CONTROL BOX...

Страница 59: ...09 1 4 holder lamp 043383 1 S lens red 043384 1 S bulb 043386 1 S gasket lamp holder 241808 1 S gasket lens 241809 1 5 pushbutton START 041967 1 6 pushbutton STOP 042235 1 7 block terminal and track 0...

Страница 60: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 UNIT TUBING...

Страница 61: ...I 250019 296 1 17 nipple close 11 4 x 31 2 822220 035 1 18 hose hydraulic 1 2 x 13 249608 006 1 19 manifold injection 227239 1 20 elbow hose 45_ 1 2 x 1 2 860008 050 1 21 hose hydraulic 1 2 x 24 24960...

Страница 62: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 UNIT TUBING...

Страница 63: ...2 040356 1 39 gasket flexible 040771 2 40 plug pipe 1 807800 040 1 41 gasket air outlet 028077 1 42 capscrew ferry head gr8 3 8 x 1 2 828406 150 4 43 adapter air outlet 250022 747 1 44 elbow 45_ 8600...

Страница 64: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 DECAL GROUP...

Страница 65: ...luid stop valve P N 016742 410239 1 9 sign warning compressor fluid fill cap 049685 1 10 sign danger air breathing 250027 935 1 11 sign warning food grade lube 250003 144 1 12 sign warning ground faul...

Страница 66: ...Boulevard Michigan City Indiana 46360 U S A Telephone 1 219 879 5451 Fax 219 874 1273 Fax 219 874 1835 Parts Fax 219 874 1288 Service SULLAIR ASIA LTD Sullair Road No 1 Chiwan Shekou Shenzhen Guangdo...