at 90 PSI Operating Pressure
Power
250 Watt
Torque
0,4 Nm
Air consumption
16,1 cfm
full load
0,46 m
3
/min
Air consumption
18,2 cfm
no load
0,52 m
3
/min
No load speed
22’000
rpm
Sound pressure
EN ISO 15744
75 dB(A)
Vibration
ISO 8662
< 2,5 m/s
2
Weight without hose
0,38 kg
Recommended air quality
DIN ISO 8573-1
3/4/4
Air hose ID
8 mm/5/16"
Collet
(refer to catalog)
up to 1/4"
Machine components:
1
Gear head
2
Insulated housing
3
Safety lever throttle
4
Valve handle
5
Grease nipple
6
Spindle
7
Collet
8
Wrench 14 mm
9
Wrench 11 mm
10
Exhaust hose
11
Muffler
12
Air hose
Recommended Accessories
13
Coupling with min ID 4.5 mm/3/16" .
1
4
1/2" Service Unit ( Capacity 5- 8 Micron).
Suitable Abrasives/Burs
General:If possible always mount shank in
collet until it bottoms out.
15
Burs, specialty abrasives,
materials conditioning products
GB
16
Mounted points, observe overhung
specification
17
Disc Pads up to 2" dia.
Additional Abrasives and Tools
can be found in the the SUHNER catalogs
Air supply requirements:
The DIN ISO quality specifications require, that
air is free of solid particles larger than 5 micron,
remaining water content to be max. 6 g/m
3
(pressure dew point+3 degree C) and air may
contain 5 mg/m
3
of oil. Therefore please
observe the following:
• Operating with dirty and unlubricated air
reduces tool life substantially.
Before installing extension hoses, blow them
clean and minimize , if at all necessary
coupling and keep them clean.
• Conserve:
Put some drops of oil in the air inlet and
briefly blow through.
Safety Instructions:
• Do not exceed max. operating speed of tool
and clamping element.
• Observe accurate mounting of insert tools.
• Observe mounting instructions for Mounted
Stones!
• Run tool for a couple of seconds under no
load, replace vibrating insert tools at once,
Protect mounted points from knocks and
grease.
• Secure work, use clamps or a vise to hold
work.
• The grinder operator shall wear safety
goggles or face shield at all times when the
grinder is in operation.
• If noise level exceeds 85 dB(A) at the work
station, operator must use ear plug and/or
ear mufflers.
For additional safety instructions
refer to enclosed brochure DL 39 220 01
Operation conditions and instructions
Safety lever throttle action
The machine can be turned on and off by
turning the lever.
1.
Turn locking lever in
direction indicated by arrow , and
2.
Depress
valve lever 3.
Technical Data
LWB 21
Содержание LWB 21-DH
Страница 12: ......