3.4 s
tArt
-
uP
/f
unctiOn
check
3.4.1 c
OmPressed
Air
cOnnectiOn
POints
Locking units (1), left linear cylinder (2), right linear cylin-
der (3).
3.4.2 P
neumAtic
diAgrAm
3.4.3 e
lectricAl
cOnnectiOn
P
in
cOnfigurAtiOn
P
in
P
Ort
s
ignAl
1
all
+V DC
2
all
-V DC
3
1
Sensor (inductive)
4
2
Photoelectric sensor
6
3
Fork light barrier
8
4
Limit switch
5
5
Limit switch
9 6 -
7 7 -
10 8 -
O
PerAting
dAtA
fOr
electricAl
distriButOr
Operating voltage
10 ... 30 V DC
Current rating per contact
1.5A
Total current
max. 1.5A
Insulationresistance
>10E9Ω
Contactresistance
5mΩ
Sensor connection
M8x1 bush, 3-pole, 0.4Nm
Control connection
M12x1 plug, 12-pole, 0.6Nm
3.5 w
Orking
instructiOns
The following listed points relating to the control and the
program are not exhaustive. They are provided for sup-
port.
It must be ensured that the driver can actually make the
abrasive rotate when the linear cylinder is moved. If this is
not the case, the driver can be readjusted within a certain
35
English
Содержание ESW 150
Страница 2: ...English Spare Parts Fran ais Pi ces de rechange Deutsch Ersatzteile 2 2...
Страница 3: ...Portug es Pe as de reposi o Espa ol Refacciones Italiano Pezzi di ricambio 3 3...
Страница 4: ...English Spare Parts Fran ais Pi ces de rechange Deutsch Ersatzteile 4 4...
Страница 5: ...Portug es Pe as de reposi o Espa ol Refacciones Italiano Pezzi di ricambio 5 5...
Страница 6: ...English Spare Parts Fran ais Pi ces de rechange Deutsch Ersatzteile 6 6...
Страница 7: ...Portug es Pe as de reposi o Espa ol Refacciones Italiano Pezzi di ricambio 7 7...
Страница 8: ...English Outline dimension Fran ais Croquis de dimensions Deutsch Massbilder 8 8...
Страница 9: ...Portug es Croquis cotado Espa ol Croquis de dimensions Italiano Piano delle dimension 9 9...
Страница 62: ...62...
Страница 63: ...63...