background image

1.2

1.1

1.3

1.4

1.5

1.1

 

Hydrolysis:

 

Programming of low salinity 
electrolysis functions.

1.2 

Level:

 Desired 

production of 
chlorine (%).

1.3 

Cover:

 Connection of 

automatic cover.  

Reduction

 of chlorine 

production in percent, when 
the pool cover is closed.

1.4 

Boost:

 Continuous 

filtration during 24 hours 
at maximum intensity. 
Automatic return to 
programmed filtration mode.  

1.5 

During the 

boost period the 
redoX control can 
be deactivated.

4.1 Hydrolysis

4.2

 Measures

2.1

2.2

2.3

2.4

2.5

2.7

2.8

2.6

2.12

2.13

2.9

2.10

2.11

2.14

2.15

2.1

 

Measures:

 

 

Adjustment of setpoints and 

measuring probes.

2.2

 

Setpoints

 for each measurement.

2.3

 Setting of setpoints.

2.4

 

Calibration of pH probe:

  

Recommended every month during 
usage season.

2.5

 

Calibration with buffers

 (buffer 

solutions pH7 / pH10 / neutral): Follow 
the instructions which appear on the 
displays (fig. 2.6).

2.7

 

Manual calibration:

 Allows to 

adjust the probes at 1 point (without 
buffers) – only recommended to 
adjust small deviation in the readings.

2.8

 Without removing 

the probe from the 
water, use the 

plus/

minus

 keys to adjust the 

reading so it matches 
with your reference value 
(photometer or other 
measurement). 

2.12

 

Manual calibration:

 

Allows to adjust 

the probes at 1 point (without buffers) – only 
recommended to adjust small deviation in 
the readings.

2.13

 Without removing the probe from the 

water, use the 

plus/minus

 keys to adjust the 

reading so it matches with your reference 
value (photometer or other measurement).

2.15

 

Temperature calibration:

 

To set the difference between the 
measured value of the probe and 
the actual temperature, use the 

plus/minus

 and 

up/down

 keys. 

Set to the actual temperature of 
the probe and press OK.

2.9

 

Calibration of the redoX 

probe:

 Recommended every 2 

months during usage season.

2.10

 

Calibration with buffer 

 

(buffer liquid 465 mV): Follow 
the instructions which appear 
on the displays (fig. 2.11).

You can access 
the display “Filter 
cleaning” from any 
filtration mode. 
Once selected this 
function, press the 
OK key.

4.3

 Filtration

3.1

 

Filtration modes

3.2

 

Manual:

 Filtration can be switched ON and OFF manually. 

3.3

 

Automatic (or with timer):

 In this mode the filtration 

switches ON/OFF according to 3 timers. The timers always 
work on daily bases. 

3.4

 

Smart*:

 

This mode uses, as a basis, the automatic or 

timer mode, with its 3 intervals of filtration, but adjusting 
the filtration time in function of the water temperature.  For 
that reason 2 parameters of temperature are provided: The 
maximum temperature, from which on the filtration times will 
be the ones from the timer setting. The minimum temperature: 
below this value the filtration time will be reduced to 5 
minutes, which is the minimum working time. Between these 
2 temperatures the filtration times will climb linearly. There 
is an option to activate the antifreeze mode in which the 
filtration will start if the water temperature is below 2° C.

3.5

 

Timed heating with option of climatization*:

 This mode 

acts equally to the automatic mode, but besides it includes 
the option to work on a relay to control the temperature. 
The desired temperature is set in this menu, and the system 
works with a hysteresis of 1 degree (example: the setting 
temperature is 23° C, the system will activate itself when 
the temperature goes below 22° C and will not stop before it 
passes 23° C).

3.7

3.1

3.2

3.3

3.6

3.5

3.4

Содержание oxilife

Страница 1: ...for advanced functions If you are an authorized installer please ask your provider for the installers service manual Connection WIFI RS module Device control SLAVE Digital inputs outputs Connection display Electrical connections of the electronic box Chlorine probe detector rotameter Cover FL1 Conductivity probe Temperature probe pH redoX Free Chlorine Low salinity electrolysis cell RCA flow detec...

Страница 2: ...lt concentrations from 2 5 g l to 50 g l s In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid Water adjustments Adding salt to the water 4 5 6 3 INITIAL WATER ADJUSTMENTS hydrolysis measures pH 7 5 OFF OFF 7 0 7 2 Rx mV 700 OFF FL1 700 man off man off 12 30 25º 100 1 2 3 4 Cover Pol 1 Low 4 FUNCTIONING OF THE SYSTEM Current time Hydrolysis Intensity of th...

Страница 3: ... actual temperature use the plus minus and up down keys Set to the actual temperature of the probe and press OK 2 9 Calibration of the redoX probe Recommended every 2 months during usage season 2 10 Calibration with buffer buffer liquid 465 mV Follow the instructions which appear on the displays fig 2 11 You can access the display Filter cleaning from any filtration mode Once selected this functio...

Страница 4: ...ting of preferred language 6 5 Setting of day and current time 6 7 Setting of the intensity of the display lighting 0 100 and programming its ON and OFF time 4 6 Settings 6 12 6 14 6 13 6 1 6 3 6 4 6 2 6 5 6 8 6 9 6 6 6 11 6 7 6 10 2 x Clima OFF The heating only works within the set filtration periods Clima ON Keeps the filtration working when the filtration period is finished if the water tempera...

Страница 5: ...ol water is not recommendable We recommend that the system runs 2 3 times per week 2 3 hours per day DOSING PUMPS Check regularly to ensure that the container contains liquid to prevent the dosing pump of running dry The dosing pump requires maintenance SEE INSTRUCTIONS ON BOX pH PROBES redoX CONDUCTIVITY Probes must be cleaned whenever necessary check every 5 6 months To clean the probe insert in...

Страница 6: ...section 3 Initial water adjustments s Check for incrustations on cell s See section 7 Electrolysis does not reach maximum intensity Electrolysis display shows LOW s The water is excessively hard and it is unbalanced s Balance the water and check the cell proceeding to clean it if necessary s Put 1 small bag of flocculant in the skimmer and recirculate 24 hours White flakes in the water s Check flo...

Отзывы: