background image

2

A

B

1

3

9

10

15

16

8

C

Conductivity probe  

(optional - for models with conductivity control)

Acid dosing pump 

(optional - for models with pH control)

Acid injector  

(optional - for models with pH control)

Hydrochloric acid container  

(optional, for models with pH control,  

not supplied with unit)

A
B
C

Filtration pump timer 

*

Silex / glass / diatom filter 
Recirculation pump

1
3

4

5

Electronic box
Low salinity electrolysis cell  

(always in vertical position) 

pH probe  

(optional - for models with pH control)

redoX probe   

(optional - for models with redoX control)

6

8

9

10

15
16

Other pool equipment
Module RF or RF/WIFI or WIFI

Product

Maximum 

consumption

Recommended 

protection

OX 1

120 W

10 A

OX 2

200 W

10 A

OX 3

400 W

16 A

OX 4

680 W

16 A

OX 5

1000 W

25 A

OX 6

1020 W

25 A

OX 7

1500 W

25 A

Electrical consumption

SYSTEM INSTALLATION

1

1

2

2

3

Adjust the alkalinity between 90 and 110 ppm’s.
Adjust the pH between 7,2 y 7,5.
Adjust the chlorine between 1 y 1,5 ppm’s.

We recommend to add 1,5 to 2,5 grams of salt 

(without iodine) for each liter of 

water in your swimming pool (1,5 to 2,5 kg NaCl per m

3

 water). 

Open the bottom valve of your swimming pool and add the salt directly to your 
swimming pool water. Let the circulation pump run during the first 24 hours.

 

s

In case the water is supplied from a well:  
Shock chlorination with trichloroisocyanuric acid  
(2 kg / 50 m

3

 of water).

 

s

Oxilife system may operate while the salt is dissolving and will operate without problems with 
salt concentrations from 2,5 g/l to 50 g/l.

 

s

In pools with strong insolation, it’s necessary to add 40 gr/m

3

 of stabiliser (isocyanuric acid).

Water adjustments

Adding salt to the water

4

5

6

3

INITIAL WATER ADJUSTMENTS

hydrolysis

measures

pH

7.5

OFF

OFF

7.0

7.2

Rx

mV

700 OFF

FL1

700

man

o

ff

man

o

ff

12:30

25º

100

%

1 2 3 4

Cover

Pol 1

Low

4

FUNCTIONING OF THE SYSTEM

Current time

Hydrolysis 

Intensity of the production in %

Automatic measurements:

 pH/redoX/ 

free chlorine/conductivity 

(according to options)

 

Communication display – mother board

red

 indicates an communication error

  

Heating ON/OFF

Manual

Automatic

Heating

Smart

Intelligent

man

aut

hea
smt

int

State filtration relay

(see section 4.3 - Filtration)

Water temperature

Production automatically reduced to 

the % selected 

(see display 

1.3

)

Pol 1

Polarity 1 / 

           

Polarity 2

Filtration stopped due to lack of water flow  

Waiting time

Flow

Low

---

Pol 2

Lack of conductivity or salt / scale on cell /  

exhausted cell 

(check working hours)

Cover

7.5

7.0

ON/OFF

AL3

Setpoint pH maximum (acid control)

Setpoint pH minimum (base control)

Function of acid pump and base pump
Maximum dosing time exceeded 

 to reset the alarm)

Flow alarm / 

           

Error rotameter Cl

2

700

FL 1

ON/OFF

FL 2

Function of chlorine pump

Setpoint redoX minimum

State relay lighting

Manual /            Automatic

man

aut

Main screen 

PLUS key

Modify value/selection

MINUS key

Modify value/selection

OK key

Select/confirm

UP key

Navigation up

DOWN key

Navigation down

RETURN/ESCAPE key

Status of the auxiliar relays

* Filtration control by external timer 

Filtration mode:
“Manual/ON”

* Filtration control by internal timer

Filtration mode:
See section 4.3

110-230 V

110-230 V

Relay 

FILTER PUMP

Содержание oxilife

Страница 1: ...for advanced functions If you are an authorized installer please ask your provider for the installers service manual Connection WIFI RS module Device control SLAVE Digital inputs outputs Connection display Electrical connections of the electronic box Chlorine probe detector rotameter Cover FL1 Conductivity probe Temperature probe pH redoX Free Chlorine Low salinity electrolysis cell RCA flow detec...

Страница 2: ...lt concentrations from 2 5 g l to 50 g l s In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid Water adjustments Adding salt to the water 4 5 6 3 INITIAL WATER ADJUSTMENTS hydrolysis measures pH 7 5 OFF OFF 7 0 7 2 Rx mV 700 OFF FL1 700 man off man off 12 30 25º 100 1 2 3 4 Cover Pol 1 Low 4 FUNCTIONING OF THE SYSTEM Current time Hydrolysis Intensity of th...

Страница 3: ... actual temperature use the plus minus and up down keys Set to the actual temperature of the probe and press OK 2 9 Calibration of the redoX probe Recommended every 2 months during usage season 2 10 Calibration with buffer buffer liquid 465 mV Follow the instructions which appear on the displays fig 2 11 You can access the display Filter cleaning from any filtration mode Once selected this functio...

Страница 4: ...ting of preferred language 6 5 Setting of day and current time 6 7 Setting of the intensity of the display lighting 0 100 and programming its ON and OFF time 4 6 Settings 6 12 6 14 6 13 6 1 6 3 6 4 6 2 6 5 6 8 6 9 6 6 6 11 6 7 6 10 2 x Clima OFF The heating only works within the set filtration periods Clima ON Keeps the filtration working when the filtration period is finished if the water tempera...

Страница 5: ...ol water is not recommendable We recommend that the system runs 2 3 times per week 2 3 hours per day DOSING PUMPS Check regularly to ensure that the container contains liquid to prevent the dosing pump of running dry The dosing pump requires maintenance SEE INSTRUCTIONS ON BOX pH PROBES redoX CONDUCTIVITY Probes must be cleaned whenever necessary check every 5 6 months To clean the probe insert in...

Страница 6: ...section 3 Initial water adjustments s Check for incrustations on cell s See section 7 Electrolysis does not reach maximum intensity Electrolysis display shows LOW s The water is excessively hard and it is unbalanced s Balance the water and check the cell proceeding to clean it if necessary s Put 1 small bag of flocculant in the skimmer and recirculate 24 hours White flakes in the water s Check flo...