2
A
B
1
3
9
10
15
16
8
C
Conductivity probe
(optional - for models with conductivity control)
Acid dosing pump
(optional - for models with pH control)
Acid injector
(optional - for models with pH control)
Hydrochloric acid container
(optional, for models with pH control,
not supplied with unit)
A
B
C
Filtration pump timer
*
Silex / glass / diatom filter
Recirculation pump
1
3
4
5
Electronic box
Low salinity electrolysis cell
(always in vertical position)
pH probe
(optional - for models with pH control)
redoX probe
(optional - for models with redoX control)
6
8
9
10
15
16
Other pool equipment
Module RF or RF/WIFI or WIFI
Product
Maximum
consumption
Recommended
protection
OX 1
120 W
10 A
OX 2
200 W
10 A
OX 3
400 W
16 A
OX 4
680 W
16 A
OX 5
1000 W
25 A
OX 6
1020 W
25 A
OX 7
1500 W
25 A
Electrical consumption
SYSTEM INSTALLATION
1
1
2
2
3
Adjust the alkalinity between 90 and 110 ppm’s.
Adjust the pH between 7,2 y 7,5.
Adjust the chlorine between 1 y 1,5 ppm’s.
We recommend to add 1,5 to 2,5 grams of salt
(without iodine) for each liter of
water in your swimming pool (1,5 to 2,5 kg NaCl per m
3
water).
Open the bottom valve of your swimming pool and add the salt directly to your
swimming pool water. Let the circulation pump run during the first 24 hours.
s
In case the water is supplied from a well:
Shock chlorination with trichloroisocyanuric acid
(2 kg / 50 m
3
of water).
s
Oxilife system may operate while the salt is dissolving and will operate without problems with
salt concentrations from 2,5 g/l to 50 g/l.
s
In pools with strong insolation, it’s necessary to add 40 gr/m
3
of stabiliser (isocyanuric acid).
Water adjustments
Adding salt to the water
4
5
6
3
INITIAL WATER ADJUSTMENTS
hydrolysis
measures
pH
7.5
OFF
OFF
7.0
7.2
Rx
mV
700 OFF
FL1
700
man
o
ff
man
o
ff
12:30
25º
100
%
1 2 3 4
Cover
Pol 1
Low
4
FUNCTIONING OF THE SYSTEM
Current time
Hydrolysis
Intensity of the production in %
Automatic measurements:
pH/redoX/
free chlorine/conductivity
(according to options)
Communication display – mother board
red
indicates an communication error
Heating ON/OFF
Manual
Automatic
Heating
Smart
Intelligent
man
aut
hea
smt
int
State filtration relay
(see section 4.3 - Filtration)
Water temperature
Production automatically reduced to
the % selected
(see display
1.3
)
Pol 1
Polarity 1 /
Polarity 2
Filtration stopped due to lack of water flow
Waiting time
Flow
Low
---
Pol 2
Lack of conductivity or salt / scale on cell /
exhausted cell
(check working hours)
Cover
7.5
7.0
ON/OFF
AL3
Setpoint pH maximum (acid control)
Setpoint pH minimum (base control)
Function of acid pump and base pump
Maximum dosing time exceeded
(
to reset the alarm)
Flow alarm /
Error rotameter Cl
2
700
FL 1
ON/OFF
FL 2
Function of chlorine pump
Setpoint redoX minimum
State relay lighting
Manual / Automatic
man
aut
Main screen
PLUS key
Modify value/selection
MINUS key
Modify value/selection
OK key
Select/confirm
UP key
Navigation up
DOWN key
Navigation down
RETURN/ESCAPE key
Status of the auxiliar relays
* Filtration control by external timer
Filtration mode:
“Manual/ON”
* Filtration control by internal timer
Filtration mode:
See section 4.3
110-230 V
110-230 V
Relay
FILTER PUMP