WARNING

Be sure the power is “OFF” to the water heater 

ignition system during any type of refueling and 

while vehicle is in motion or being towed.
The  thermostat  on  your  water  heater  is 

adjustable.  It  is  a  temperature  sensing  limit 

designed  to  maintain  a  water  temperature  of 

120°F (48°C) from the factory. (See Operating 

Instructions)  Water  temperatures  over  125°F 

(52°C)  can  cause  severe  burns  instantly  or 

death from scalds; therefore, be careful when 

using hot water. Children, disabled and elderly 

are at highest risk of being scalded. Always feel 

water before bathing or showering.

INSTALLATION REQUIREMENTS

 

WARNING

Installation of this appliance must be made in 

accordance with the written instructions provided 

in  this  manual.  No  agent,  representative  or 

employee  of  Suburban  or  other  person  has 

the  authority  to  change,  modify  or  waive  any 

provision  of  the  instructions  contained  in  this 

manual.

 

CAUTION

A Suburban vent cap must be installed on the unit and all 

side inspection panels must be in place for proper water 

heater operation.
If possible, do not install the water heater to where the 

vent can be covered or obstructed when any door on the 

trailer  is  opened.  If  this  is  not  possible,  then  the  travel 

of  the  door  must  be  restricted  in  order  to  provide  a  6” 

minimum clearance between the water heater vent and 

any door whenever the door is opened.
Due to the differences in vinyl siding, this appliance should 

not be installed on vinyl siding without first consulting with 

the manufacturer of the siding or cutting the siding away 

from the area around the appliance vent.
In any installation in which the vent of this appliance can 

be covered due to the construction of the RV or some 

special feature of the RV such as slide out, pop-up etc., 

always insure that the appliance cannot be operated by 

setting the thermostat to the positive “OFF” position and 

shutting off all electrical and gas supply to the appliance.
Do not install this appliance to where the vent terminates 

below  a  slide-out.  This  appliance  is  not  to  be  installed 

under any overhang. It must be free and clear of any type 

overhang.

 

SAFETY WARNING

Should  overheating  occur,  or  the  gas  supply 

fail to shut off, shut off the manual gas valve to 

the appliance before shutting off the electrical 

supply.
Do not use this appliance if any part has been 

submerged  under  water.  Immediately  call 

a  qualified  service  technician  to  inspect  the 

appliance and to replace any part of the control 

system  and  any  gas  control  that  has  been 

submerged under water.
Do not alter the operation of your water heater 

nor  change  the  design/construction  of  your 

water heater. Accessories are being marketed 

for RV products which we do not recommend. 

For  your  safety,  only  factory  authorized  parts 

are to be used on your water heater.
Periodically  inspect  the  vent  for  obstructions 

or presence of soot. Soot is formed whenever 

combustion  is  incomplete.  This  is  your  visual 

warning that the water heater is operating in an 

unsafe manner. If soot is present, immediately 

shut  the  water  heater  down  and  contact  your 

dealer or a qualified service person.
When considering add-on rooms, porch or patio, 

attention  must  be  given  to  the  venting  of  your 

water heater. For your safety, do not terminate 

the  vent  on  your  water  heater  inside  add-on 

rooms, screen porch or onto patios. Doing so will 

result  in  products  of  combustion  being  vented 

into the rooms or occupied areas.
Never operate the appliance if you smell gas. 

Do  not  assume  that  the  smell  of  gas  in  your 

RV is normal. Any time you detect the odor of 

gas, it is to be considered life threatening and 

corrected  immediately.  Extinguish  any  open 

flames  including  cigarettes  and  evacuate  all 

persons from the vehicle. Shut off gas supply at 

LP gas bottle. (See Safety notice on front cover 

of this manual.)

 

WARNING

Do  not  store  or  use  combustible  materials 

or  liquids  near  or  adjacent  to  this  heater. The 

appliance shall not be installed in any location 

where flammable liquids or vapors are likely to 

be present.

2

Содержание NAUTILUS IW60

Страница 1: ...ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER INSTALLER AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO WATER HEATER OWNER RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE ALL TECHNICAL...

Страница 2: ...ly to the appliance Do not install this appliance to where the vent terminates below a slide out This appliance is not to be installed under any overhang It must be free and clear of any type overhang...

Страница 3: ...ket supplied with the kit apply the gasket beginning at the center bottom of the replacement panel frame Adhere the adhesive side of the gasket to the replacement panel frame and install the gasket al...

Страница 4: ...th the door open OPERATING INSTRUCTIONS WITH SWITCH AND LIGHT ASSEMBLY 1 STOP Read the safety information above 2 Turn off all electric power to the appliance 3 Turn OFF gas supply 4 Wait five minutes...

Страница 5: ...crease the SET water temperature in single increments Refer to OPERATING INSTRUCTIONS WITH OPTIONAL ON DEMAND CONTROL CENTER and see Figure 13 LOW TEMPERATURE RISE AND EXCESSIVE WATER FLOW REQUIRED TO...

Страница 6: ...pply to heater 3 Shut off water supply Drain water from system 4 Disconnect HOT and COLD water lines from water heater 5 Remove screws at the back of the unit 6 Remove vent cap assembly 7 Remove water...

Страница 7: ...1 2 I D TUBING Figure 5 VENT CAP PART NO 260617 SHOWN FOR INSTALLATION WITHOUT ACCESS PANEL MAX X DIMENSION OF 2 00 1 250 MIN OVERLAP REQUIRED ON EXHAUST X ON DEMAND WATER HEATER EXHAUST VENT TUBE TRA...

Страница 8: ...AROUND OPENING 8 SCREWS 4 SCREWS MOUNTING TABS IN FRAME 2 SLOTS IN BOTTOM OF PANEL HOOK IN TABS ON FRAME BEFORE INSTALLING 5 SCREWS TO SECURE PANEL BOTTOM OF PANEL SILICONE OR CAULKING AROUNG OPENING...

Страница 9: ...AIN 5 8 I D TUBING SYSTEM DRAIN CONTROL KNOB FREEZE PROTECTION NEEDLE VALVE CONDENSATE DRAIN 1 2 I D TUBING GREEN GROUND SCREW Figure 10 Figure 9 SERVICE PANEL MANUAL ECO SWITCH LEFT SIDE ACCESS PANEL...

Страница 10: ...MPERATURE PROBE OUTLET WATER TEMPERATURE PROBE WH WH BR BR Y R GAS VALVE 2 STAGE GAS VALVE R SPARK ELECTRODE ON DEMAND CONTROL CENTER MOTOR WH O BR Y GY R BL WIRE HARNESS SWITCH R LAMP BK MODULE BOARD...

Страница 11: ...reached the display stops flashing after a few seconds B When the demand for hot water has been terminated the display will return to the SET Temperature C When the water heater is turned off the lett...

Страница 12: ...IONS MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHOMSOEVER SUBURBAN WILL NOT...

Страница 13: ...ENTE GARANTIE SONT EXCLUSIVES ET NE PEUVENT PAS TRE MODIFI ES TENDUES OU CHANG ES PAR UN DISTRIBUTEUR UN CONCESSIONNAIRE OU UNE AUTRE PERSONNE QUELLE QU ELLE SOIT SUBURBAN NE SERA PAS TENUE RESPONSABL...

Страница 14: ...hage cesse de clignoter au bout de quelques secondes B Lorsque la demande en eau chaude prend fin l affichage retourne la temp rature de consigne C Lorsque le chauffe eau est teint les lettres OF s af...

Страница 15: ...OURNI AVEC L APPAREIL DOIT ETRE REMPLACE LE REMPLACER PAR UN MATERIAU DE CABLAGE AYANT UNE TEMPERATURE MINIMALE D AU MOINS 80 C 176 F CAL 20 600 V 105 C 221 F CAL 18 600 V 105 C 221 F MISE EN GARDE N...

Страница 16: ...BOUTON DE COMMANDE DE LA VIDANGE DU CIRCUIT AIGUILLE DE SOUPAPE FREEZE PROTECTION VIDANGE DU CONDENSATS 1 2 PO DIMENSIONS INTERNES TUBE VERT SOL VIS Figure 10 Figure 9 PANNEAU D ENTRETIEN INTERRUPTEUR...

Страница 17: ...OU CALFEUTRE AUTOUR DE L OUVERTURE POUR LE PANNEAU D ACCES 37 8 LITERS 10 GALLONS LE CAS ECHEANT 4 VIS 5 VIS APPLIQUER DU SILICONE AUTOUR DU COTE ARRIERE DU TROU D AERATION DIOT ETRE SCELLE AU PANNEA...

Страница 18: ...DU CONDENSATS 1 2 PO DIMENSIONS INTERNES TUBE Figure 5 PI CE POUR BOUCHON D VENT NO 260617 MONTR E POUR L INSTALLATION SANS PANNEAU D ACC S DIMENSIONS MAX X DE 5 08 cm X ON DEMAND WATER HEATER CLAPET...

Страница 19: ...HEATER 1 Fermer l alimentation en gaz et d brancher le tuyau d alimentation en gaz du chauffe eau 2 D brancher l alimentation 12 Vcc du chauffe eau 3 Fermer l alimentation en eau vacuer l eau du syst...

Страница 20: ...Si votre chauffe eau n cessite un d bit excessif pour tre activ plus de 1 9 LPM il est possible que de l eau FROIDE soit purg e dans le c t de l eau CHAUDE de votre syst me de distribution d eau 1 V r...

Страница 21: ...br leur ne s allume pas le syst me tentera automatiquement d effectuer deux autres essais d allumage avant le verrouillage Lorsque la lumi re demeure allum e le syst me est en mode verrouillage 8 Si...

Страница 22: ...URBAN 22 7 LITRES 6276APW Blanc polaire SUBURBAN 37 8 45 42 60 5 LITRES 6277APW Blanc polaire ATWOOD 22 7 LITRES 521147 Blanc polaire ATWOOD 37 85 LITRES 521150 Blanc polaire NUM RO DE PI CE DU BOUCHO...

Страница 23: ...e l unit est recommand e pour att nuer l accumulation de charge lectrostatique en fixant un fil isol de mise de terre de calibre 12 au bo tier de l unit la vis de terre verte illustr e la Figure 5 et...

Страница 24: ...APPOSER CES INSTRUCTIONS SUR OU PROXIMIT DU CHAUFFE EAU PROPRI TAIRE CONSERVER CES INSTRUCTIONS ET LA GARANTIE AUX FINS DE CONSULTATION ULT RIEURE TOUTES QUESTIONS DE NATURE TECHNIQUE OU RELATIVES LA...

Отзывы: