background image

°C/°F

11

OPTIONAL ON DEMAND CONTROL CENTER

Figure 13

Figure 14

MOUNTING HOLES

KNOCK OUT

DISPLAY DESCRIPTION

1

BURNERS

                      2 BURNERS

                      5 BURNERS

2

FLAME

This  icon  is  displayed  when 

FLAME is established.

3

BLOWER

This  icon  is  displayed  when  the 

BLOWER is running

4

STATUS 

INDICATOR

This  icon  is  displayed  when  the 

Water Heater is in standby mode, 

ready to be used.

5

SETTING TEMP 

INDICATOR; 

OUTLET WATER 

TEMP INDICATOR

A. 

When setting the water temperature, 

the  temperature  display  will  flash.  

After  SET  Temperature  is  reached, 

the  display  stops  flashing  after  a  few 

seconds.

B. 

When the demand for hot water has 

been terminated, the display will return 

to the SET Temperature.

C. 

When the water heater is turned off, 

the letters "OF" will be display.

6

FREEZE 

PROTECTION

This  icon  is  displayed  when 

the  FREEZE  PROTECTION 

MECHANISIM is engaged.

BUTTON DESCRIPTION

7

ON/OFF

Power Button.  Switch from turning 

unit ON or turning unit OFF.

8

°C/°F

SWITCH

Hold  for  5  seconds  to  switch 

between  degrees  (°)  Celcius  or 

degrees (°) Fahrenheit

9

UP

INCREASE  SET  Temperature 

by 1 degree increments.  Setting 

range is 35°C/95°F to 55°C/130°F

10

DOWN

DECREASE  SET  Temperature 

by 1 degree increments.  Setting 

range is 35°C/95°F to 55°C/130°F

1

2

3

4

5

7

8

9

10

6

Содержание NAUTILUS IW60

Страница 1: ...ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER INSTALLER AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO WATER HEATER OWNER RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE ALL TECHNICAL...

Страница 2: ...ly to the appliance Do not install this appliance to where the vent terminates below a slide out This appliance is not to be installed under any overhang It must be free and clear of any type overhang...

Страница 3: ...ket supplied with the kit apply the gasket beginning at the center bottom of the replacement panel frame Adhere the adhesive side of the gasket to the replacement panel frame and install the gasket al...

Страница 4: ...th the door open OPERATING INSTRUCTIONS WITH SWITCH AND LIGHT ASSEMBLY 1 STOP Read the safety information above 2 Turn off all electric power to the appliance 3 Turn OFF gas supply 4 Wait five minutes...

Страница 5: ...crease the SET water temperature in single increments Refer to OPERATING INSTRUCTIONS WITH OPTIONAL ON DEMAND CONTROL CENTER and see Figure 13 LOW TEMPERATURE RISE AND EXCESSIVE WATER FLOW REQUIRED TO...

Страница 6: ...pply to heater 3 Shut off water supply Drain water from system 4 Disconnect HOT and COLD water lines from water heater 5 Remove screws at the back of the unit 6 Remove vent cap assembly 7 Remove water...

Страница 7: ...1 2 I D TUBING Figure 5 VENT CAP PART NO 260617 SHOWN FOR INSTALLATION WITHOUT ACCESS PANEL MAX X DIMENSION OF 2 00 1 250 MIN OVERLAP REQUIRED ON EXHAUST X ON DEMAND WATER HEATER EXHAUST VENT TUBE TRA...

Страница 8: ...AROUND OPENING 8 SCREWS 4 SCREWS MOUNTING TABS IN FRAME 2 SLOTS IN BOTTOM OF PANEL HOOK IN TABS ON FRAME BEFORE INSTALLING 5 SCREWS TO SECURE PANEL BOTTOM OF PANEL SILICONE OR CAULKING AROUNG OPENING...

Страница 9: ...AIN 5 8 I D TUBING SYSTEM DRAIN CONTROL KNOB FREEZE PROTECTION NEEDLE VALVE CONDENSATE DRAIN 1 2 I D TUBING GREEN GROUND SCREW Figure 10 Figure 9 SERVICE PANEL MANUAL ECO SWITCH LEFT SIDE ACCESS PANEL...

Страница 10: ...MPERATURE PROBE OUTLET WATER TEMPERATURE PROBE WH WH BR BR Y R GAS VALVE 2 STAGE GAS VALVE R SPARK ELECTRODE ON DEMAND CONTROL CENTER MOTOR WH O BR Y GY R BL WIRE HARNESS SWITCH R LAMP BK MODULE BOARD...

Страница 11: ...reached the display stops flashing after a few seconds B When the demand for hot water has been terminated the display will return to the SET Temperature C When the water heater is turned off the lett...

Страница 12: ...IONS MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHOMSOEVER SUBURBAN WILL NOT...

Страница 13: ...ENTE GARANTIE SONT EXCLUSIVES ET NE PEUVENT PAS TRE MODIFI ES TENDUES OU CHANG ES PAR UN DISTRIBUTEUR UN CONCESSIONNAIRE OU UNE AUTRE PERSONNE QUELLE QU ELLE SOIT SUBURBAN NE SERA PAS TENUE RESPONSABL...

Страница 14: ...hage cesse de clignoter au bout de quelques secondes B Lorsque la demande en eau chaude prend fin l affichage retourne la temp rature de consigne C Lorsque le chauffe eau est teint les lettres OF s af...

Страница 15: ...OURNI AVEC L APPAREIL DOIT ETRE REMPLACE LE REMPLACER PAR UN MATERIAU DE CABLAGE AYANT UNE TEMPERATURE MINIMALE D AU MOINS 80 C 176 F CAL 20 600 V 105 C 221 F CAL 18 600 V 105 C 221 F MISE EN GARDE N...

Страница 16: ...BOUTON DE COMMANDE DE LA VIDANGE DU CIRCUIT AIGUILLE DE SOUPAPE FREEZE PROTECTION VIDANGE DU CONDENSATS 1 2 PO DIMENSIONS INTERNES TUBE VERT SOL VIS Figure 10 Figure 9 PANNEAU D ENTRETIEN INTERRUPTEUR...

Страница 17: ...OU CALFEUTRE AUTOUR DE L OUVERTURE POUR LE PANNEAU D ACCES 37 8 LITERS 10 GALLONS LE CAS ECHEANT 4 VIS 5 VIS APPLIQUER DU SILICONE AUTOUR DU COTE ARRIERE DU TROU D AERATION DIOT ETRE SCELLE AU PANNEA...

Страница 18: ...DU CONDENSATS 1 2 PO DIMENSIONS INTERNES TUBE Figure 5 PI CE POUR BOUCHON D VENT NO 260617 MONTR E POUR L INSTALLATION SANS PANNEAU D ACC S DIMENSIONS MAX X DE 5 08 cm X ON DEMAND WATER HEATER CLAPET...

Страница 19: ...HEATER 1 Fermer l alimentation en gaz et d brancher le tuyau d alimentation en gaz du chauffe eau 2 D brancher l alimentation 12 Vcc du chauffe eau 3 Fermer l alimentation en eau vacuer l eau du syst...

Страница 20: ...Si votre chauffe eau n cessite un d bit excessif pour tre activ plus de 1 9 LPM il est possible que de l eau FROIDE soit purg e dans le c t de l eau CHAUDE de votre syst me de distribution d eau 1 V r...

Страница 21: ...br leur ne s allume pas le syst me tentera automatiquement d effectuer deux autres essais d allumage avant le verrouillage Lorsque la lumi re demeure allum e le syst me est en mode verrouillage 8 Si...

Страница 22: ...URBAN 22 7 LITRES 6276APW Blanc polaire SUBURBAN 37 8 45 42 60 5 LITRES 6277APW Blanc polaire ATWOOD 22 7 LITRES 521147 Blanc polaire ATWOOD 37 85 LITRES 521150 Blanc polaire NUM RO DE PI CE DU BOUCHO...

Страница 23: ...e l unit est recommand e pour att nuer l accumulation de charge lectrostatique en fixant un fil isol de mise de terre de calibre 12 au bo tier de l unit la vis de terre verte illustr e la Figure 5 et...

Страница 24: ...APPOSER CES INSTRUCTIONS SUR OU PROXIMIT DU CHAUFFE EAU PROPRI TAIRE CONSERVER CES INSTRUCTIONS ET LA GARANTIE AUX FINS DE CONSULTATION ULT RIEURE TOUTES QUESTIONS DE NATURE TECHNIQUE OU RELATIVES LA...

Отзывы: