Page 4
Induction Range (IR) Series
Induction Range (IR) Series
Electronics
2-4
#827176 - Revision A.2 - September, 2017
Timer
General Information
Available in any mode except Lock Mode.
•
The 2-digit display is blank unless there is a fault, in Diagnostic Mode, or Showroom Mode.
•
Shows minutes until the timer reaches 1 minute.
•
Switches to seconds at 1 minute, and counts down from 60 seconds.
•
Timer is paused until 3 seconds after the last change in value then countdown begins.
•
Adjusting the time on a running timer resets the seconds to zero.
•
If counting down seconds and the
“-”
pad is touched the timer stops without alarm.
•
Maximum time allowed is 99 minutes.
•
Minimum time allowed is 1 minute.
•
Timer turns off after 10 seconds if no time is entered.
•
Starting the Timer
1.
Unlock the cooktop.
2.
Press and release the
TIMER
pad.
3.
Time increases and decreases with a touch of the
“+”
or
“-”
pad.
4.
If the
“+”
or
“-”
pad is held continuously for 3 intervals the count rate increases.
5.
If the
“+”
or
“-”
pad is held continuously for additional 3 intervals, the count rate increases again.
6.
A continuously held
“+”
or
“-”
increases in this manner: 00, 01, 02, 03, 04, 05, 10, 15, 20, 30, 40, 50, 60,
70, 80, 90, 99.
Ending the Timer
At 60 seconds the One Minute Remaining beep sounds.
•
At 00 the Timer Complete beep sounds until acknowledged.
•
Touch of the
TIMER
or
“-”
pad stops Timer Complete beep and clears the display.
•
Touch of the
“+”
pad adds time to the timer as described above.
•
Display States of the Timer
When active the 2-digit display and Timer are on.
•
Other displays are as described in Idle Mode or Operational Mode.
•
Fans
Fan control is determined by the temperature on the heat sinks.
•
Both fans of a three or four coil assembly generator start simultaneously on low speed.
•
If one heatsink reaches the threshold temperature, only that fan speed is increased.
•
A very high power request, such as two elements on 100% or one on boost switches the fans on independently
•
of the heatsink temperature.
After generator is off fan continues to run until heat sink temperature is below 113° F, or up to 600 seconds.
•
Fan is limited to low speed when the generator is off.
•
Temperature thresholds:
•
113° F – start low speed
•
131° F – start high speed