Style selections SSFBD28T Скачать руководство пользователя страница 23

23

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often. 

PILOT FLAME PATTERN

 

1. Turn control knob to pilot position.

2. Inspect pilot flame and refer to Fig. 20 and 21. 

• Fig. 20 shows a correct pilot flame pattern. 

• Fig. 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not

  touching the thermocouple. This will cause the thermocouple to cool. When the 

  thermocouple cools, the heater will shut down. 

• If the pilot flame is incorrect, as shown in Fig. 21, turn heater off (see “To Turn 

  Off Gas to Appliance,” page 22). See Troubleshooting, page 26 - 28.

Fig. 20 - Correct Pilot Flame Pattern

Fig. 22 - Correct Pilot Flame Pattern with    

Control Knob Set to High Flame (5)

Fig. 23 - Incorrect Pilot Flame Pattern 

with Control Knob Set to High Flame (5)

Fig. 21- Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

 

Fig. 22 shows a correct burner flame pattern. Fig. 23 shows an incorrect burner flame pattern. 

• If burner flame is incorrect, as shown in Fig. 23, turn heater off (see “To Turn Off Gas to  

 

  Appliance”, page 22).

• see Troubleshooting, pages 26 through 28.

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the entrance to the burner.

These holes may become blocked with dust or lint. Periodically inspect these holes for

any blockage and clean as necessary. Blocked air holes will create soot.

More than 8 in. above top of logs

Approx. 3-6 in. above top of logs

Содержание SSFBD28T

Страница 1: ...e not prohibited by local codes This appliance is for use with the type of gas indicated on the rating plate only This appliance is not convertible for use with other gases This is an unvented gas fir...

Страница 2: ...ng installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM 0030334 VENT FREE GAS FIREPLACE INSERT Input Rating 26...

Страница 3: ...GAS Natural and Propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no...

Страница 4: ...ff If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 7 Always run heater with control knob at PILOT or ON locked positions...

Страница 5: ...ng and the heater burning manufacturing residues QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories...

Страница 6: ...d plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale o...

Страница 7: ...of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In most supplemental...

Страница 8: ...egate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are considered a p...

Страница 9: ...er logs ________ BTU hr Gas water heater 30 000 BTU hr Other gas appliances ___BTU hr Vent free heater 26 000 BTU hr Total ________________ BTU hr Total 56 000 BTU hr Do not include direct vent gas ap...

Страница 10: ...the two spaces see options 1 and 2 Fig 2 You can also remove door into adjoining room see option 3 Fig 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for req...

Страница 11: ...etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free...

Страница 12: ...ons shown in Fig 8 for the rough opening The height is 26 1 2 in which is the same as the wall opening above 2 Carefully set fireplace in front of rough opening with back of fireplace inside wall open...

Страница 13: ...ombustible materials to cover any necessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front of the firebox Step 1 Step 3 Step 2 Fig 9 Remove two screws on to...

Страница 14: ...eptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never connect heater to private non utility gas wells This gas...

Страница 15: ...recommend that you install a sediment trap in a supply line as shown in Fig 12 Locate sediment trap where it is within reach for cleaning and not likely to freeze Install in the piping system between...

Страница 16: ...of a quarter and turn knob clockwise until the knob locks into the NG position see Fig 14 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal hex plug with wr...

Страница 17: ...17 Fig 15 Fig 14 Fig 13 NATURAL GAS PROPANE GAS PLUG NATURAL GAS PROPANE GAS PLUG...

Страница 18: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig 16 2 Pressure supply...

Страница 19: ...ns in this manual Flames contacting logs will create soot Fig 18 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Fig 18 It is very important to install the logs exactly...

Страница 20: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Страница 21: ...ing ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob p...

Страница 22: ...ollow steps 1 through 5 under Lighting Instructions 3 With control knob in PILOT position strike match and hold near pilot Press in control knob pilot should light 4 Keep control knob pressed in for 3...

Страница 23: ...ame Pattern Fig 22 Correct Pilot Flame Pattern with Control Knob Set to High Flame 5 Fig 23 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 Fig 21 Incorrect Pilot Flame Pattern BUR...

Страница 24: ...ean the pilot assembly also WARNING Failure to keep primary air openings of burners clean may result in sooting and property damage CAUTION You must keep control areas burner and circulating air passa...

Страница 25: ...You may blow through a drinking straw if compressed air is not available CABINET Air Passageways Use a vacuum cleaner or pressurized air and a small soft bristled brush to clean Exterior Use a soft cl...

Страница 26: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electro...

Страница 27: ...orifice 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 24...

Страница 28: ...r furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products H...

Страница 29: ...have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the...

Страница 30: ...2 BL037 02 B 8 LOG 3 BL038 02 B 9 LOG 4 BL041 02 10 LOG 5 FB28D505 C 11 SCREEN FB28D07 B 12 LOWER FRONT ACCESS DOOR FB28D415 B 01 13 UPPER DECORATIVE TRIM FB28D12B B REPLACEMENT PARTS LIST For replac...

Страница 31: ...ccident misuse improper installation or by affixing accessories not produced by the manufacturer are the purchaser s responsibility The manufacturer assumes no responsibility whatsoever for installati...

Отзывы: