LIGHTING INSTRUCTIONS
Unscrew ignitor cap and install a AAA battery (included) with the + pointing out. Replace cap.
1.
STOP!
Read the safety information on page 20.
2.
Warning
: You must operate this heater with the screen in place. Make sure screen is installed
before running heater.
3. Turn control knob clockwise to the OFF position, see Fig. 19, page 22.
4. Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near floor. If
you smell gas,
STOP
! Follow "B" in the safety information on Warnings plate. If you don't
smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT position. Keep control knob pressed in for
five (5) seconds.
Note
: You may be running this heater for the first time after hooking up to gas
supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to
bleed from the gas system. If control knob does not pop up when released, contact a qualified '
service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This will light pilot.The
pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot
lights.
Note
: If pilot does not stay lit, contact a qualified service person or gas supplier for
repairs. Until repairs are made, light pilot with match.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release
control knob.
Note
: If pilot goes out, repeat steps 3 through 7. This heater has a safety
interlock system. Wait one (1) minute before lighting pilot again.
8.
WARNING
: Make sure that while the input gas type is NG, pilot burner NG ignites; while the
input type is LP, pilot burner LP ignites. Note: If you find anything abnormal in this step, repeat
steps 2 through 8.
9. Turn control knob counterclockwise to the desired heating level. The main burner should light.
Set control knob to any heat level between HI and LO (5 –1).
THERMOSTATIC CONTROL OPERATION
The thermostatic control used on this model differs from standard thermostats. Standard
thermostats simply turn the burner on and off. The thermostat used on this heater senses the
room temperature. At times the room may exceed the set temperature. If so, the burner will shut
off. The burner will cycle back on when room temperature drops below the set temperature. The
control knob can be set to any comfort level between HIGH (5) and LOW (1).
Note
: The thermostat sensing bulb measures the temperature depending on housing
construction.