2 – Job
Ignored if Item Number is 0.
Batch Reset
USINT
When this value changes, the batch counts of the currently running
parameter or group is reset.
Suspend
BOOL
When set, suspends the unit without stopping a running parameter, group,
or job.
Batch
USINT
Sets the batch size for the selected parameter. If Item Type is not 0
(Parameter), this value is ignored. If this value is 0, the parameter size
stored in the Global 400 will be used.
VIN
SHORT_STRING Max length 100
Total size: 7-107 bytes
163
Name
Data Type
Description
Item Number
UINT
Instance number of item to run. Deactivate any running parameter, job,
or group if 0.
Item Type
USINT
Type of item to run:
0 - Parameter
1 – Group
2 – Job
Ignored if Item Number is 0.
Batch Reset
USINT
When this value changes, the batch counts of the currently running
parameter or group is reset.
Suspend
BOOL
When set, suspends the unit without stopping a running parameter, group,
or job.
Batch
USINT
Sets the batch size for the selected parameter. If Item Type is not 0
(Parameter), this value is ignored. If this value is 0, the parameter size
stored in the Global 400 will be used.
Total size: 6 bytes
Input (T->O) Connection Points
This section defines the connection points are used by Global 400 to send output data to the
network. The connection points are in the range 100-129 and are grouped by their content.
•
10x: Connection points provided for backwards compatibility with the Global 8. (Detailed in
the
Input Connection Points for Backwards Compatibility
section later in this chapter)
•
11x: Last tightening data
•
12x: Current qualifier status
Input Connection Points for Last Tightening Data
The connection points in this group will contain data about the last tightening. As such, they are
not updated after a parameter, group, or job selection until a tightening occurs.
110
Name
Data Type
Description
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Multi Sequence
Number
UINT
Sequence number of the running multi-parameter operation.
Multi Number
UINT
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Содержание Global 400
Страница 1: ...Global 400 User Manual v1 1 revision 1 2 February 2016 Manual Part Number 857412...
Страница 4: ...Global 400 User Manual 4 of 85 v1 1 revision 1 Quick Start 2 February 2016 Quick Start...
Страница 59: ...Global 400 User Manual 59 of 85 v1 1 revision 1 Chapter 6 ToolsNet 2 February 2016 Chapter 6 ToolsNet...
Страница 62: ...Global 400 User Manual 62 of 85 v1 1 revision 1 Chapter 7 EtherNet IPTM 2 February 2016 Chapter 7 EtherNet IPTM...