TECHNICAL FEATURES

•LAMPS

•OPTIC COLOUR SYSTEM
Full CYM unlimited variety of colours and 2 colours (red and pink)
Color filter corrector (from 6500°K to 3200°K)
High resolution stepper motors

•BEAM ANGLE
Beam angle (50%): WxH 40°x45° or 45°x40°
New concept optical system with rotating parabole to illuminate the surface with maximum horizontal or vertical beam opening
Motorised variation of the beam opening

•SETUP AND CONFIGURATION
Control panel with graphic LCD display and smart reading by DMX start address by a triple led display
Easy and intuitive program and setup by a dynamic menu and four buttons
Real time monitor and full control of lamp power and all electronic ballast parameters 
Stand-alone control: auto mode function master/slave (syncro mode) with 5 non editable standard programs and 4 programmes 
for customization by the user
Built-in REAL TIME CLOCK for synchronised auto switch-on/off which is operated on a weekly timer (weekly schedule)

•CONTROL INPUT
Standard interface: RS-485; opto-couplet input
Protocol: USITT DMX 512

•DMX CHANNELS
1=motor speed
2=pink
3=red
4=filter corrector
5=yellow
6=cyan

•POWER SUPPLY
Rated voltage:  95-265V 47-63Hz (Electronic Ballast)
Fuses:  

2x8A

Rated power: 

1000Va

Rated current:  4.5A (230V)  -  9A (117V)

•POWER FACTOR CORRECTOR: built-in cos Ø 0.99

•IP RATE = IP 66 

•DIMENSIONS (wxdxh): mm 650x610x740

•WEIGHT: Kgs. 62,0

Check that the fixture has not been damaged during transport. If it has been damaged or it does not work, 

address  the  seller. Whether the fixture has been shipped to you directly, please contact the shipping company.

Only the consignee (person or company) can claim for these damages.

WARNING

!

Lamps

BA 800 SE

MSD 575 HR

Available lamps

Colour temperature

5.600° K

6.000° K

HMP 575 SE

Lamp life

1.000 hours

3.000 hours

MSR 575 HR

Luminous flux

65.000 lm

43.000 lm

MSA 600 SE

Colour rendering index

(Ra) > 90

(Ra) > 90

Burning position

universal

universal

7=magenta
8=dimmer
9=aux
10=beam angle
11=remote reset- lamp on/off

Содержание 0305

Страница 1: ...User s and operator s manual for art 0305 PROVISIONAL...

Страница 2: ...page 2 Technical features page 3 Before using page 4 Lamp installation replacement and setting page 5 Beam angle setting page 6 Control panel page 8 Control panel configuration and fixture management...

Страница 3: ...alls or any other type flammable surfaces 3 Maintain minimum distance to lighted objects of 5 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot close to heat so...

Страница 4: ...ynchronised auto switch on off which is operated on a weekly timer weekly schedule CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 DMX CHANNELS 1 motor speed 2 pink 3...

Страница 5: ...e connection cable on the spot when it is warm b This unit must be positioned as to allow its ventilation c The unit must be positioned at least 50 cm from walls or other flammable surfaces d Observe...

Страница 6: ...lamp support plate pict 4 6 Remove the lamp holder D and insert the lamp into the lampholder pict 5 Do not touch the quarz bulb with fingers If this happenes clean the bulb before use with dry cloth a...

Страница 7: ...on the head cover and remove it pict 5 2 Loosen the two pommels P under the dicrhoic group I pict 5a 3 Rotate clockwise of 45 the parabole up to stop it pict 6 and 6a 4 Screws the two pommels P pict 6...

Страница 8: ...the four screws Q 4 Remove the wire protection U 5 Open the other three spring lock S on the three side of the dichroic unit I 6 Unscrew and remove the wire protection V 7 Disconnect the connecter Z a...

Страница 9: ...s Sub menus This icon shown that is possible directly to insert the values Choosed menu change the values EXAMPLE 1 ICON EXAMPLE 2 ICON 1 2 1 2 icon UTILITY Programs Master Auto Define User O k E s c...

Страница 10: ...progressive 256 levels value 0 255 RESET lamp SWITCHING OFF value 0 127 no operation 128 191 motor reset 192 239 no operation 240 250 lamp turning off 251 255 no operation ON BOARD CONTROL PANEL BASIC...

Страница 11: ...er U1 1 EDIT U2 modify record preset user U2 EDIT U3 modify record preset user U3 EDIT U4 modify record preset user U4 ADVANCED LANGUAGE to choose language AUTO TST function test FIXT RESET reset item...

Страница 12: ...ING OF A PRESET USER To edit any PRESET it s important that the equipment both set for working in DMX For the mode operative enter in the menu UTILITY so in the sub menu PROGRAMS The first voice sign...

Страница 13: ...break of time fixed 4 Insert the week day or the combination of days which the program at hand it must to be carry out Once introduced all parameters save the program and exit with ESC The program MM...

Страница 14: ...o essere soggette a variazioni senza preavviso Rev 1 800e 06 2004 Asia branch STUDIO DUE Far East LTD Unit D 29 F West Gate Tower 7 Wing Hong Street Kln Hong Kong tel 852 29542141 fax 852 23302515 Hea...

Отзывы: