Thank you for choosing the Hercules800e !

The Hercules800e projects, thanks to an extremely efficient optic system (PATENT PENDING), a powerful light beam which can create 
numberless color shades. Its performances, in terms of luminousity and lighted surfaces, can reach incredible levels.
New concept optical system (WxH 40°x45° or 45°x40°) with rotating parabole to illuminate the surface with maximum horizontal or 
vertical beam opening 

The Hercules800e comes in unique version:

• Art. 0305     HERCULES 800E

The Hercules800e can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers

The input protocol is the DMX 512. To drive the Hercules800e we suggest to use either our controller Control Show 512, Fancy or 
the Easy Control.

To make  the most  of its possibilites and for a correct  functioning of this unit in the years to come, we suggest you to read carefully 
this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and connections 
and you will be easily able to use it.

WARNING

!

SAFETY INFORMATION

READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.

INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS AND 

UV RADIATION HAZARDS.

• PROTECTION AGAINTS FIRE

1) This equipment is designed for use with the following lamps only: 

BA 800SE, MSD 575HR

    Other available lamps: 

HMP 575SE, MSA 600SE, MSR 575HR

.

    

DO NOT USE ANY OTHER TYPE LAMP!

2) Maintain minimum distance of 0.5 meter from walls or any other type flammable surfaces.
3) Maintain minimum distance to lighted objects of 5.0 meter.
4) Replace fuses only with the specified type and rating.
5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.

• PROTECTION AGAINST ELECTRIC SHOCK

1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) For connection to the mains supply proceed as page 4. The equipment must be connected to branch circuit having a
    circuit- breacker In=10A Id=0.03A (230VAC) 
4) Disconnect power before lamp’s replacement or servicing (service personnel).

• PROTECTION AGAINST MECHANICAL HAZARDS

1) Use secondary safety chain when fixing this equipment.
2) Hot lamp explosion hazard. Do not open the equipment for 600 seconds after switching off.
3) Equipment surface may reach temperature up to 100°C. Allow about five minutes before handling.
4) Replace the lamp if it is damaged or thermally deformed.

• PROTECTION AGAINST UV RADIATION HAZARDS

1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged.
2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
    has been reduced, for example, by cracks or deep scratches.
3) Do not look directly at the lamp while lamp is on.

YOUR REFERENCE

Always remember to give the serial number and to specify the model any time you address the seller for information or assistan-
ce.

BASIC KIT

The basic kit of the Hercules800e flood projector consist of:
•Projector
•User’s manual
•Power connector
•Studio Due warranty

Available on request:
•Lamp

Содержание 0305

Страница 1: ...User s and operator s manual for art 0305 PROVISIONAL...

Страница 2: ...page 2 Technical features page 3 Before using page 4 Lamp installation replacement and setting page 5 Beam angle setting page 6 Control panel page 8 Control panel configuration and fixture management...

Страница 3: ...alls or any other type flammable surfaces 3 Maintain minimum distance to lighted objects of 5 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot close to heat so...

Страница 4: ...ynchronised auto switch on off which is operated on a weekly timer weekly schedule CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 DMX CHANNELS 1 motor speed 2 pink 3...

Страница 5: ...e connection cable on the spot when it is warm b This unit must be positioned as to allow its ventilation c The unit must be positioned at least 50 cm from walls or other flammable surfaces d Observe...

Страница 6: ...lamp support plate pict 4 6 Remove the lamp holder D and insert the lamp into the lampholder pict 5 Do not touch the quarz bulb with fingers If this happenes clean the bulb before use with dry cloth a...

Страница 7: ...on the head cover and remove it pict 5 2 Loosen the two pommels P under the dicrhoic group I pict 5a 3 Rotate clockwise of 45 the parabole up to stop it pict 6 and 6a 4 Screws the two pommels P pict 6...

Страница 8: ...the four screws Q 4 Remove the wire protection U 5 Open the other three spring lock S on the three side of the dichroic unit I 6 Unscrew and remove the wire protection V 7 Disconnect the connecter Z a...

Страница 9: ...s Sub menus This icon shown that is possible directly to insert the values Choosed menu change the values EXAMPLE 1 ICON EXAMPLE 2 ICON 1 2 1 2 icon UTILITY Programs Master Auto Define User O k E s c...

Страница 10: ...progressive 256 levels value 0 255 RESET lamp SWITCHING OFF value 0 127 no operation 128 191 motor reset 192 239 no operation 240 250 lamp turning off 251 255 no operation ON BOARD CONTROL PANEL BASIC...

Страница 11: ...er U1 1 EDIT U2 modify record preset user U2 EDIT U3 modify record preset user U3 EDIT U4 modify record preset user U4 ADVANCED LANGUAGE to choose language AUTO TST function test FIXT RESET reset item...

Страница 12: ...ING OF A PRESET USER To edit any PRESET it s important that the equipment both set for working in DMX For the mode operative enter in the menu UTILITY so in the sub menu PROGRAMS The first voice sign...

Страница 13: ...break of time fixed 4 Insert the week day or the combination of days which the program at hand it must to be carry out Once introduced all parameters save the program and exit with ESC The program MM...

Страница 14: ...o essere soggette a variazioni senza preavviso Rev 1 800e 06 2004 Asia branch STUDIO DUE Far East LTD Unit D 29 F West Gate Tower 7 Wing Hong Street Kln Hong Kong tel 852 29542141 fax 852 23302515 Hea...

Отзывы: