43
Ins cleaning
and
disinfecting
probe
Cleaning and disinfecting alarm.
Possible solutions:
- check the correct insertion of the spike probe
Main consequences:
- the cleaning and disinfecting cycle will be stopped.
Cleaning and
disinfecting
duration
Alarm for cleaning and disinfecting not over within the maximum duration (HACCP
alarm).
Possible solution:
- check that the first phase of cleaning and disinfecting lasts less than 5 hours (default
parameter)
Main consequences:
- the device will register the alarm
- the running cycle will be stopped
- the alarm exit will be activated.
Over-heated
condenser
Over-heated condenser alarm.
Possibile solution:
- verify the temperature of the condenser
Main consequence:
- The alarm exit will be activated
Stalled comp
Stalled compressor alarm.
Possible solutions:
- verify the temperature of the condenser (if above 60°C the compressor will be stalled)
- unplug the device and clean the condenser
Main consequences:
- if the error occurs during the stand by, it
won’t
be possible nor to select or to start any
cycle.
- if the error occurs during a cycle, the cycle will be interrupted.
- the alarm exit will be activated.
Spike probe
insertion
Spike probe
“not inserted” alarm.
Possible solutions:
- verify il correct insertion of the spike probes
Main consequences:
- the temperature based cycle will be switched in a time based once