Introduction 

The SI sinewave inverters have been designed 
to meet industrial and domestic needs. They 
satisfy the highest demands of comfort, safety 
and reliability.  
 
Any device designed for the public electrical 
network of 230V / 50 Hz can be connected to 
them. 
 
The SI inverters are  the perfect solution as 
sources of tension in any place where the public 
network is not available. 
 
Read the connection instructions thoroughly and 
give them to the technician who is to install the 
inverter so as to prevent any malfunction. Thus 
you will have a modern and reliable installation 
which meets requirements. 
 
Should you have any doubt or question, do not 
hesitate to contact your specialist salesperson 
who will give you the best advice.

 

Note 

A deficient assembly could damage the device, 
cause function failures or potential damage to 
the users.  
 
The working device generates a high tension 
which might be fatal in case of contact. So, any 
manipulation of the inverter must be carried out 
with utmost care. The following points must be 
strictly observed : 
 
The installation of the "SI" can only be 
performed by a qualified technician. 
 
In case of malfunction, only a technician 
specially designated and trained by STUDER 
INNOTEC is allowed to repair the device.  

Warning : 

Opening the inverters or using them 

incorrectly will result in the immediate 

loss of the warranty. 

No current or tension generating devices (public 
network, generator, ...) may be connected  to 
the output of the inverter because this could 
result in its destruction.  

As for the usage of batteries, follow the 
manufacturer’s instructions

Important : 

After disconnecting the battery, the output 

tension (230V) may still remain for 30 

seconds. 

The ventilation of the device should never be 
obstructed. Should the device be installed in an 
enclosed structure, make sure that  ventilation is 
possible and adequate. 
 
The installation and assembly of the device 
must follow the rules stipulated. 
 
This document is an essential part of the 
inverter and must always be carried with it and 
be at the disposition of anyone working on the 
installation

Applications and Performance 

As well as its modern design and its technical 
characteristics, the SI inverter is also easy and 
economical to use in almost all applications. 
 
All devices working within the public electrical 
network (230V - 50Hz) may be used with the 
inverter (up to its nominal power).  
 
The inverter generates a perfectly sinusoid 
output tension, precisely adjusted by a high 
technology regulation system. 
 
Thus, the output tension is totally independent of 
the charge and the fluctuation of tension in the 
battery. 
 
All inverters in the SI series are protected 
against overloading and short circuits. 
 
Due to obvious safety reasons, the inverter is 
not automatically reactivated after a failure 
(overload, short circuit,…).

 

Product presentation 

The inverters of the SI series are presented fully 
equipped, with battery cables, 230V cable and 
the user's handbook

Содержание SI 1212

Страница 1: ...User manual SI V3 0 E Sinewave inverter SI SERIES User s and Installer s Handbook STUDER INNOTEC Rue des Casernes 57 CH 1950 Sion Tel 41 0 27 205 60 80 Fax 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Страница 2: ...ment procedure 5 CONTROL 5 INDICATORS 5 Green Run LED 3 5 Red Fault LED 2 5 SAFETY 5 INTERNAL FUSE 5 OPTIONS 6 ALARM CONTACT 6 SOLAR CHARGE CONTROLLER 6 LED Charging 11 6 LED Bat 100 10 6 MAINTENANCE 6 LEGISLATION 6 LIMITATION OF LIABILITY 6 CE DECLARATION OF CONFORMITY 6 DESCRIPTION AND WIRING DIAGRAM 7 WIRING DIAGRAM FOR SI 600 800 S SOLAR CHARGE REGULATOR 8 SI PERFORMANCE ERREUR SIGNET NON DEFI...

Страница 3: ...rranty No current or tension generating devices public network generator may be connected to the output of the inverter because this could result in its destruction As for the usage of batteries follow the manufacturer s instructions Important After disconnecting the battery the output tension 230V may still remain for 30 seconds The ventilation of the device should never be obstructed Should the ...

Страница 4: ...ing the polarity in order not to damage the device Check that the connections are fixed correctly Use After connecting the inverter make sure the user devices are correctly plugged in and that there is no possible contact between the Line OUT 6 and a person The working device generates high tensions which could be fatal The inverter can be activated by moving the switch to the Auto position The on...

Страница 5: ...n the following ranges 11 4 V and 16 V in the 12 Volt models 22 8 V and 32 V in the 24 Volt models 45 6 V and 61 V in the 48 Volt models Outside these ranges the inverter is automatically disconnected These values correspond to a no load situation and they are automatically adjusted according to the current of the battery The internal temperature and the maximum power are also submitted to control...

Страница 6: ...on for control Legislation In all cases the assembly and installation must be done by qualified technicians observing the national requirements and rules stipulated You will find complete information about this in the relevant institutions Limitation of liability STUDER INNOTEC cannot control the installation use and maintenance of the inverter Thus we are not responsible for damages costs or loss...

Страница 7: ...STUDER INNOTEC SI User manual SI V3 0 E 7 Description and wiring diagram ...

Страница 8: ...STUDER INNOTEC SI User manual SI V3 0 E Wiring diagram for SI 600 800 S Solar charge regulator ...

Страница 9: ...d together in order to obtain a 3 400V 3 phased grid Connecting 1 Check that the inverters are in OFF position 2 First link together the neutral of all 3 devices by taking care that this connecting point be not further than 1 m from each inverter 3 Link together the battery cables take care to not reverse the polarity The 3 inverters have to be connected together to only one battery bank Commissio...

Страница 10: ...imum power 15 min 1 3 1 6 x Pnom 25 C Maximum power 3 min 1 6 2 x Pnom 25 C Peak power 5s 3 5 x Pnom Asymmetric load Up to 2 x Pnom Cos ϕ 0 1 1 Protections Overload Overheat Short circuit Reverse polarity by internal fuse IP protection index IP 20 complies with DIN 40050 IP 23 with top cover Forced ventilation From 45 C 3 C Overheating protection 75 C 3 C Required battery capacity 5x Pnom Unom rec...

Отзывы: