Sine wave inverter 19’’ – HPSI serie

 

 
 

The series of industrial sine 
wave inverters in 19’’ rack is 
directly developed from our SI 
series. The HPSI range gains 
therefore from a high reliability 
and suits especially well to in-
dustrial and professional appli-
cations. 

 

  
 
 
 
 
 
 
 
 
 
 
 

 

           HPSI 4424 

 
Technical specifications 

 

HPSI 

in 19” rack 

 

HPSI 2212 

HPSI 4424

 

HPSI 5048

 

Input voltage [Unom]

 

12V 24V

 

48V

 

Nominal power

 

2200W 4400W

 

5000W

 

Standby current [mA] 
Power ON no load standby power

 

30 

15W 

35 

<20W

 

30 

<30W

 

Power ON no load  
TWINPOWER system

 

-------- --------

 

--------

 

Maximum efficiency

 

91% 95%

 

95%

 

Weight [kg]

 

35 51

 

57

 

Height

 [HE] x 

depth [mm]

 

264 (6U) x 450

 

Input voltage

 

< Unom x 0.95 - Unom x 1.33 

>

 

 

Output voltage

 

Sinus 230 Vac +/- 3% 

 

Distortion

 

< 2% (at Pnom))

 

Dynamic behaviour

 

Normalization 0.5 ms for 0% to 100% load 

 

Frequency

 

50 Hz +/- 0.01%(Crystal control)

 

Charge detection

 

User adjustable: 0.5 to 20 W

 

Maximum power load 15 min.

 

1.3 – 1.6 x Pnom / 25°C 

 

Maximum power load 3 min.

 

1.6 - 2 x Pnom / 25°C

 

Peak power 5 sec.

 

3.5 x Pnom

 

Asymmetric charge

 

Up to 2 x Pnom

 

Cos 

φ

 max. at Pnom

 

0.6 - 1

 

IP protection index

 

IP 20

 

Forced ventilation

 

From 45°C +/- 3°C

 

Overheating protection

 

75°C +/- 3°C

 

Required battery capacity

 

>

 5 x Pnom/Unom (recommended value)

 

Acoustic level

 

Without ventilation : < 20 dB With ventilation: < 45 dB

 

EC conformity

 

EN 50081 I/II, EN 55014 – 55022, IEC 801 II / III / IV, CEI 555, EN 60950

 

 Data are for information only and may change without notice 
 
 

Other standard features: 
. remote control possibility 
. potential free alarm contact (60V/1A) 

 

 
 

        

 
 

Options

 

HPSIxxxxTP TWINPOWER 

system

 

HPSIxxxxPE 

3-phase for 3 x 400V systems                                                          

Rear view of HPSI 4424

545/HPSI

 

Содержание HPSI 2212

Страница 1: ...2 at Pnom Dynamic behaviour Normalization 0 5 ms for 0 to 100 load Frequency 50 Hz 0 01 Crystal control Charge detection User adjustable 0 5 to 20 W Maximum power load 15 min 1 3 1 6 x Pnom 25 C Maximum power load 3 min 1 6 2 x Pnom 25 C Peak power 5 sec 3 5 x Pnom Asymmetric charge Up to 2 x Pnom Cos φ max at Pnom 0 6 1 IP protection index IP 20 Forced ventilation From 45 C 3 C Overheating protec...

Страница 2: ...tallers Handbook HPSI V2 0 E page1 Sinewave inverter HPSI series User s and Installer s Handbook STUDER INNOTEC Rue des Casernes 57 CH 1950 Sion Tel 41 0 27 205 60 80 Fax 41 0 27 205 60 88 info studer inno com www studer inno com ...

Страница 3: ... 4 CONNECTION 4 USE 4 REMOTE CONTROL 4 Standby Level 1 4 Adjustment procedure 4 CONTROL 5 INDICATORS 5 Green Run LED 3 5 Red Fault LED 2 5 SAFETY 5 INTERNAL FUSE 5 ALARM CONTACT 5 MAINTENANCE 5 LEGISLATION 5 LIMITATION OF LIABILITY 5 DECLARATION OF CONFORMITY 7 EQUIVALENT CIRCUIT FOR HPSI INVERTER 8 DESCRIPTION AND WIRING DIAGRAM 9 TECHNICAL SPECIFICATIONS 10 ...

Страница 4: ...c network generator may be connected to the output of the inverter because this could result in its destruction As for the usage of batteries follow the manufacturer s instructions Important After disconnecting the battery the output tension 230V may still remain for 30 seconds The ventilation of the device should never be obstructed Should the device be installed in an enclosed structure make sur...

Страница 5: ...ected the LED blinks after some seconds which indicates that the standby mode has started If a user device is plugged in the green LED remains illuminated indicating the uninterrupted presence of 230V in the outlet If you wish to deactivate the standby mode put the switch in Lock position The inverter will be then working continuously Warning With the lock mode the no load consumption of the inver...

Страница 6: ...inverter after a failure put the switch 4 in OFF position for 10 seconds then connect again Safety The inverter is internally protected against overloads and short circuits Should this protection fail the inverter is equipped with a fuse fire protection If the fuse is broken qualified technicians should control the installation and change the fuse Internal fuse Fuse Inverter HPSI CF8 fuse links 30...

Страница 7: ...s with potential risks of serious harm to people or to the environment We do not accept any responsibility for any violation of patent rights or other third person rights resulting from the use of the inverter STUDER INNOTEC reserves the right to modify their products without previous notice ...

Страница 8: ...57 CH 1950 Sion Declares that the product Sinewave inverter Product Name HPSI Series Model Number HPSI 2212 HPSI 4424 HPSI 5048 Are conform to the following product specifications EN 50081 I II EN 55014 EN 55022 EN 50091 2 EN 60950 IEC 801 II III IV CEI 555 LVD 73 23 EEC EMC Dir 89 336 EEC Full name position Date Signature Roland Studer General director 16 02 2000 ...

Страница 9: ...blue wire and the yellow green wire This point can also be tied to ground if there is an existing ground Every ground point of appliances or plug should be tied together One side or the other of plus or minus battery input could also be tied to ground if needed A real neutral is an absolute need if there is a FI ground fault detector used as safety device In any case he installation of an inverter...

Страница 10: ...Inverter stop when contact is closed Main switch Run indicator Green LED Fault indicator red LED Standby level adjustment Not avalable with Twinpower option Battery connection Minus battery Alarm contact 60V 0 5A potential free 9 2 3 Check battery polarity Battery size sould be ajusted to the inverters power Cbatt Ah 5 x Pnom Unom This value could be divided by two for short time applications 6 ...

Страница 11: ...trol Charge detection User adjustable 0 3 to 20 W Maximum power charge 15 min 1 3n 1 6 x Pnom 25 C Maximum power charge 3 min 1 6 à 2 x Pnom 25 C Peak power 5 sec 3 5 x Pnom Asymmetric charge Up to 2 x Pnom Cos ϕ max at Pnom 0 6 1 IP protection index IP 20 Forced ventilation From 45 C to 3 C Overheating protection temperature 75 C 3 C Required battery capacity 5x Pnom Unom recommended value Acoust...

Отзывы: