Studer Innotec SA
BSP
14
V1.3
User manual
4.3
R
ESET THE BATTERY HISTORY TO ZERO
If you install the BSP for the first time or if the battery has been changed, you must reset the battery
history to zero, by means of the parameter {6003}.
5
DISPLAY OF THE STATE OF THE BATTERY
On installations with a BSP, the view over information on the
battery is added to the RCC.
In area (A), four values of the BSP are displayed. The symbol of
the battery in (B) gives a quick overview of the state of charge
(SOC). The direction of the current is given in (C). An arrow
upwards means the charge, downwards, the discharge.
5.1
G
RAPH OF THE STATE OF CHARGE HISTORY
It is possible to see the battery state of charge of the last 5 days
on the RCC. On that purpose, from the view over the battery
information, you enter in selection mode with the key SET. The
battery is then selected. The key SET allows then to display the
graph.
The graph of the state of charge is then displayed. On the
horizontal scale are today and the last 4 days. The graduations
indicate every hour from midnight to midnight. Each horizontal
pixel means one hour. The vertical axis gives the state of charge
of the battery. The graduations mean 20, 40, 60, 80 and 100 % and
one pixel means 2 %.
5.2
V
ALUES TO DISPLAY
It is possible to modify the values to display on the battery view. For that, from the basic view of
the battery monitor push SET. The battery is then selected and is illustrated in black. Go to the first
value displayed with the key DOWN. The keys UP and DOWN allow going to the field to configure.
With the key SET, enter the menu corresponding to the value to display.
Then, choose the value to display by means of UP and DOWN and push on SET to validate.
At any time, to quit, use the key ESC that will bring you to the previous view.