Connecting the Welding Leads
1. Connect the stud gun weld cable into the gun terminal socket on the front of the welding unit. The
cable end plug has a flat which aligns with a dot on the panel mount socket. Secure the connector
into the panel mount socket, and then turn it clockwise until it locks into proper position.
Failure
to properly make these connections could result in damage to the connectors.
2. Connect the weld gun control cable into the center socket connector. The control cable plug has a
large pin and a small pin that match the socket on the unit. Push the plug firmly into the socket
and twist clockwise to secure the plug into the correct position.
3. Connect the ground clamp into the ground terminal socket on the front of the unit, this connec-
tion is identical to step 1.
Connecting the Ground Clamp
1. Prior to securing the clamp, make certain that
the contact area is free of rust, paint, grease, or
any other impurities to ensure a good ground
connection.
2.
Attach the clamp of the welding ground lead to
the work piece.
3.
Most applications will require only one ground
clamp
, but certain applications will require an
additional dual clamp.
SETUP AND WELDING
9
Stud Gun
Weld
Cable
Connection
Ground
Cable Connection
Stud Gun
Control
Cable
Connection
WWW.STUDWELDPROD.COM
800-252-1919