Stuart Turner Flomate iBoost 46668 Скачать руководство пользователя страница 6

- 6 -

Cont ...

2  LOCATION - GENERAL

2.11

 Access: 

For emergencies and maintenance the pump must be  

 

 

 

easily accessible.

2.12

 Protection:

 The iBoost must be located in a dry, frost free area.  The   

 

 

iBoost must not be installed in a loft space.

2.13 

Ventilation:  

Ensure an adequate air flow to cool the iBoost.  

 

 

 

Separate the iBoost from other appliances that generate heat. 

Do not

  

 

 

block the vent holes on the front panel.

2.14

 Safety: 

Motor is not accessable in normal operating mode.  Unit must  

 

 

only be operated with the front cover in place.

2.15

  Water retention:

 Site the iBoost in a location where in the unlikely    

 

 

event of overflow, water leak, any spillage is contained or routed to    

 

 

avoid electrics or areas sensitive to water damage. 

 

The iBoost has a weir type overflow at the rear of the tank, in the  

 

 

event of overflow, the water will drain from the weir area. 

 

A minimum gap of 50 mm must be allowed at the rear of the tank to    

 

allow any possible overflow water to exit the weir area.  

The weir  

 

 

area must not be blocked or covered.

2.16

  Supply inlet pressure:

 The water supply inlet pressure must be lower than  

 

 

7 bar; lower supply inlet pressures will reduce the tank fill rate and reduce the    

 

time the iBoost will run at higher flow rates before running out of stored water.

2.17

  Ambient temperature:

 The iBoost must be sited in a location where the  

 

 

ambient temperature does not exceed 30 

o

C (see Section 7.13 - Water   

 

 Quality).
2.18

 Pipework:

 For optimum performance outlet pipework must be 22 mm pipe.     

 

Pipework should only reduce to 15 mm when entering terminal fittings.

2.19

  Static outlet pressure:

 The static outlet head must also be within the  

 

 

maximum requirement of 15 metres (vertically above the appliance).

2.20 

Noise:

 A flexible hose is supplied as standard which will minimise the    

 

 

transmission of noise and vibration from the iBoost pump to the pipework  

 

 

connected to the appliance outlet.  However, care must be taken when mounting 

 

the iBoost that any noise is not amplified through loose panels or pipework.

2.21

  Direction of flow: 

Ensure the water flow is in the direction of the arrow marked  

 

on the flow switch reed clamp (vertically upwards).

2.22

  Flexible hose:

 Only use the Stuart Turner hose supplied with the pump.

2.23 

Isolating valves:

  Separate system isolating valves (non restrictive) must be    

 

fitted to allow easy pump service.  Isolating valves must be mounted where  

 

 

specified to allow the system isolation and removal of the iBoost if needed. See   

 

Section 4

 

for installation details.

2.24 

Preferred iBoost location:

 The preferred iBoost location is on a smooth level   

 

floor of sufficient strength to support the filled weight of the iBoost close to the    

 

water source and a suitable overflow position (see Section 8 - Technical  

 

 

Specification for filled weight).

 

The iBoost must not be installed in a loft space.

 

It must also be considered that the noise and vibration from the iBoost may be    

 

transmitted through the structure the iBoost is sited on.

 

Ensure there is sufficient room above the iBoost to allow the removal and  

 

 

servicing of the internal float valve if needed, typically 350 mm.

Содержание Flomate iBoost 46668

Страница 1: ...instruction booklet with the home owner as it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the followin...

Страница 2: ...ldren aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use...

Страница 3: ...4 Important Facts read before commencing installation 5 Location 6 Key Features 7 Installation Pump Connections 8 Electrical Installation 12 Commissioning 15 Maintenance 17 Technical Specification 19...

Страница 4: ...ve Item Description Qty Item Description Qty Flomate iBoost CAT 5 1 M6 screw 1 Hose sealing washer 1 Instruction book 1 Retaining strap 1 Installation template 1 A E C B D F Fig 1 IMPORTANT With the a...

Страница 5: ...ost this will cause damage and possible leakage 1 17 Flux Solder joints must be completed and flux residues removed prior to iBoost installation flux damage will void any warranty 1 18 Pipework design...

Страница 6: ...rmance outlet pipework must be 22 mm pipe Pipework should only reduce to 15 mm when entering terminal fittings 2 19 Static outlet pressure The static outlet head must also be within the maximum requir...

Страница 7: ...Drain valve Tank Tank access cover Mains water connection User interface User interface cable Pump module Pump module retaining screws Pump isolation valve behind pump Note iBoost CAT 5 shown with fro...

Страница 8: ...Water outlet pipework 1 The pump has a G threaded connection to accept the supplied hose The hose is made water tight with a sealing washer on assembly nip tight to 4 to 5 Nm for water tight seal Do n...

Страница 9: ...ide 2 m high cupboard If installed into a 600 mm cupboard the floor and back panel will need to be removed and the cupboard spaced forward to allow the 50 mm clearance at the rear to allow for the wei...

Страница 10: ...ntable fittings push fit or compression where shown in Fig 7 The positioning of these fittings allow the iBoost to be removed without cutting pipes or draining the system Fig 7 Overflow Non pumped wat...

Страница 11: ...ble wall using a suitable fastening system 4 15 It is recommended that at least one drinking water tap is connected into the un pumped mains water supply typically a kitchen sink so the water supply i...

Страница 12: ...e earthed via the supply cord which must be correctly connected to the earth point located in the terminal box 5 17 Pipework Copper or metallic pipework must have supplementary earth bonding where the...

Страница 13: ...or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be con...

Страница 14: ...nd routing system Re assemble to the same pattern For information on cable connection consult the wiring diagram and cable gland fitting instructions 5 25 Cable Gland Fitting Instructions To enable co...

Страница 15: ...er from the storage tank can be isolated from the pump by use of the isolation valve behind the pump 6 13 System Flushing The pipework system should be flushed out prior to the iBoost being connected...

Страница 16: ...rn associated with the pump including w c systems allowing water to flow from each outlet until all air is purged As each outlet is opened and closed the pump will start and stop respectively Note Aft...

Страница 17: ...seal to stick if left without use for long periods The pump must be run for at least 5 minutes every four weeks to exercise all working parts See Section 8 Technical Specification for note on water te...

Страница 18: ...is supplied with clear protective film in place this can be removed by lifting at the edge 7 16 Float fill valve The float level is factory set but if in time the water level in the tank is found to...

Страница 19: ...hylene Pump body Brass stainless steel Impeller Stainless steel Performance Maximum head closed valve 4 5 bar 450 kPa Maximum flow 100 l min Maximum inlet pressure tank fill valve 7 bar 700 kPa Maximu...

Страница 20: ...ue to run Contact Stuart Turner Damaged reed switch P C B or pressure switch If pump continues to run this indicates a closed circuit in either the flow switch reed pressure switch or P C B in the ter...

Страница 21: ...water supply problem 4 Press and hold the Reset button for 2 seconds 5 The pump will re start and function provided the water supply is maintained During the re start the nearest lowest outlet in the...

Страница 22: ...nstallation improper use unauthorised repair normal wear and tear and defects which have a negligible effect on the value or operation of the product Reasonable evidence must be supplied that the prod...

Страница 23: ...co uk and complete a short form which will enable visitors to find your contact details on our web site installer finder Alternatively use your smartphone to scan this QR code and go straight to the f...

Страница 24: ...BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 1999 519 EC BS EN 62233 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTO...