- 18 -
Cont ...
7.14 The tank can be drained by either:
a) Isolating the mains water supply to the fill valve and using the pump to pump
the water out of the tank.
or
b) Isolating the water supply to the tank and attaching a flexible hose to the
drain valve (see Fig. 15).
7.15
Front cover and keypad cleaning:
The front cover is made from acrylic
capped ABS, it must only be cleaned with warm soapy water or mild detergent.
Do not
use abrasive cleaners. The front cover is supplied with clear protective
film in place, this can be removed by lifting at the edge.
7.16
Float fill valve:
The float level is factory set but if in time the water level in the
tank is found to be too high, the level can be adjusted by moving the float
assembly on the arm of the fill valve down (see Fig. 16). Access the float fill
valve by removing the lid of the tank (see Section 3 - Key Features). This is done
by loosening the M6 retaining screw and sliding the float assembly down
(reduce dimension X), the M6 screw is then retightened ensuring the float is still
in line with the arm.
Fig. 15
Drain valve
Do not
overtighten
Fig. 16
M6 retaining screw
‘X’