- 13 -
Cont ...
5.21
Wiring of connection unit:
WARNING: This appliance must be earthed.
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral Brown: Live
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your
connection unit proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal
in the connection unit which is marked with the letter E or by the earth
symbol:
or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is
marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is
marked with the letter L or coloured red.
5.22
Wiring Diagram:
Model
Fuse Size (AMPS)
iBoost
10
5.23
Fuses:
The following fuse size should be used:
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
FLOWSWITCH
REED (S3)
BL
AC
K
RE
D
RED
GREEN / YELLOW
BLUE
BROWN
L
E
N 230 VAC/1PH/50Hz
SUPPLY
N
M
N
L
PRESSURE
SWITCH (S1)
S2 S3 S3 S2 S1
S1
0V
D1
D2 D3 SW
0V
MOTOR
PCB
28480
D1
D2
D3
SW1
0V
0V
LED 1
LED 2
LED 3
SW 1
COMM 1
PIN 1
PIN 6
KEYPAD
28481
CABLE
20047
ORA
NGE
GR
EEN
RE
D
W
HI
TE
BLAC
K
BLUE
R1
R2
R3
6 4 2
5 3 1
YELLOW