MAINTENANCE
Turn off water supplies to the pump and release pressure by
opening water outlets before attempting maintenance
10.1
Inlet Strainer
The inlet strainers may require periodical cleaning. The frequency of this operation
is dependent upon installation conditions. The strainer is located in the inlet
assembly of the pump casing and is removed as follows:
1.
Isolate pump electrically.
2.
Release all system pressure.
3.
Isolate hot and cold water supplies via the integral pump isolating valve
located in the flexible hoses and release hose nuts connected to the pump
(see Section 7- Pump Connections).
4.
Remove M4 screws (2 off) from inlet assembly, lift brass inlet fitting (with O-
ring) away from pump casing (Figure 16).
5.
Remove strainer with long nose pliers noting location lug position upon
removal (Figure 16) and clean thoroughly.
6.
Refit strainer taking care to position lug in body inlet port location slot and
re-assemble pipework. Tighten M4 clamp screws to 1.5 Nm torque.
7.
Re-connect flexible hoses and tighten (see Section 7.2).
8.
After maintenance is completed refer to Section 9 – Commissioning for
instructions on re-starting pump.
Figure 16