13
6.4
Cold Water Connection
The cold water supply: Must be a DEDICATED AIR FREE
supply via a tank
connector, and must be positioned at a slightly lower level (25 mm minimum) than
the feed pipe to the hot water cylinder.
Ensure that the pipework size from the cold water tank is 22mm minimum.
Do not connect to the mains.
6.5
Hot Water Connection
Hot water cylinder or storage tank:
When a hot water cylinder or storage tank is
used, ensure the pipework size from the cold water storage to the hot water
storage is of adequate size and a minimum of 22 mm for all model except the
S4.5 bar twin which should be a minimum of 28 mm.
Hot water supply
: The pump
must be
supplied with a
dedicated feed
direct from
the hot water cylinder or storage tank, ensuring an air free connection to the
pump. We recommend the use of either the Side Entry Flange (SE) Part No 27900
or a Top Entry Flange (TE) Part No 27800 (for all models except the S4.5 bar Twin;
S4.5 bar Twin should only use ‘A’ or ‘D’). Please note both flange options listed
above are designed to suit 22 mm pipework. If used in ROI a suitable adaptor to 21
mm pipe must be used (not supplied).
Expansion pipe
: When the method of connection is to be made via the expansion
pipe, the
BASE
of the cold water storage tank
MUST
be at least 1 metre above the
connection/take off of the hot water storage cylinder feeding the pump.
Figure 6
Off expansion
pipe with rising
28mm offset
reducing to
22mm pipework
to pump and
expansion pipe.
Off expansion
pipe with rising
22mm offset
and 22mm
pipework to
pump.
Top Entry
Flange (Part No
27800) with
22mm pipework
to pump.
Factory installed G
¾
secondary tapping with
22mm pipework to
pump.
Or
Side Entry Flange (Part
No 27900) with 22mm
pipework to pump.
30
°
- 45
°
30
°
- 45
°
For applications in
ROI pipe sizes above
should read 21 mm.
A
B
C
D